Acidic Potassium Dichromate Solutions as Ultraviolet Absorbance Standards*

نویسنده

  • R. W. Burke
چکیده

. The absorbances of five concentrations of potassium dichromate in 0.001 ]l.f perchloric aCid have been determined at eight wavelengths in the ultraviolet on the National Bureau of Standards Institute for Materials Research high-accuracy spectrophotometer. Four of the wavelengths-235, 257, 313, and 3.50 nm-correspond to absorbance maxima or minima in the HCrO,spectrum and are useful wavelengths for checking the accuracy of the absorbance scale of narrow bandpass speetrophotometers. Although partial dimerization of nCrO,to Cr207prod~c.e~ small positive deviations from Beer's law at these wayelengths, the apparent absorptlvltles calculated for each concentration arc reproducible to one part in a thousand. The estimated uncertainties in the absorptivity values are ± 0.7 percent at 0.1 absorbance (A) and ± 0.2 percent ncar A = 1. These uncertainties include all known sources of possible systematic error and the 95 percent confidence level for the mean. The remaining four wavelengths used for measurement arc ncar two predicted isosbestie points in the HCrO,~/Cr207sp~ctra . The absorptivities at 345 nm arc sufficiently independent of concentratIOn that thiS wavelength can be used for checking absorbance linearity to one part in a thousand over the range A = 0.2-1.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect spectrophotometric determination of some biologically important phenothiazines using potassium dichromate, iron(II) and 1,10-phenanthroline

A sensitive method is presented for the spectrophotometric determination of phenothiazine derivatives of biological importance. The drugs namely, chlorpromazine hydrochloride (CPH), promethazine hydrochloride (PH), trifluoperazine hydrochloride (TFPH), prochlorperazine maleate (PCPM) and fluphenazine hydrochloride (FPH) are reacted with a fixed amount of dichromate in acidic conditions. After t...

متن کامل

Evaluation of the stability of iron(II) solutions by precise coulometric titration with electrogenerated cerium(IV).

An iron(II) solution is often used as a reducing agent in titrimetry and standardized with cerium(IV) or potassium dichromate. Such an iron(II) standard solution is needed for not only titrimetric analyses, but also instrumental ones. Iron(II) is unstable even in a highly acidic solution, mainly due to air-oxidation; therefore, its standardization is required before use. In the present study...

متن کامل

Procedure for calibrating the Technicon Colorimeter I.

We describe a rapid method for calibrating the Technicon AutoAnalyzer colorimeter I. Test solutions of bromphenol blue are recommended for the calibration, in preference to solutions of potassium dichromate, based on considerations of the instrument's working range and of the stray light characteristics of the associated filters.

متن کامل

Lithium Aluminum Hydride Reactions in Pyridine Solution. Reductive Cleavage of Ketones1

contain 5.1 g. of 3-ethylpentane by vapor phase chromatography. The above material was purified by shaking with potassium permanganate solution followed by vapor phase chromatography ($6~ 1.3929). Final purification was effected by dissolving it in 10 ml. of acetic acid and adding solution of sodium dichromate and perchloric acid in 90% acetic acid until the orange color persisted. Water was ad...

متن کامل

Exploiting gas diffusion for non-invasive sampling in flow analysis: determination of ethanol in alcoholic beverages.

A tubular gas diffusion PTFE membrane is exploited for non-invasive sampling in flow analysis, aiming to develop an improved spectrophotometric determination of ethanol in alcoholic beverages. The probe is immersed into the sample, allowing ethanol to diffuse through the membrane. It is collected into the acceptor stream (acidic dichromate solution), leading to formation of Cr(III), monitored a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010