Risk factors of atrial fibrillation recurrence despite successful radiofrequency ablation of accessory pathway: At 11 years of follow-up.

نویسندگان

  • Michał Orczykowski
  • Piotr Urbanek
  • Robert Bodalski
  • Paweł Derejko
  • Grzegorz Warmiński
  • Małgorzata Łodyga
  • Damian Łasocha
  • Łukasz Mazurkiewicz
  • Maciej Dąbrowski
  • Paweł Tyczyński
  • Joanna Zakrzewska-Koperska
  • Rafał Baranowski
  • Artur Oręziak
  • Maciej Sterliński
  • Maria Bilińska
  • Łukasz Szumowski
چکیده

BACKGROUND Previous reports on patients with radiofrequency catheter ablation (RFCA) of accessory pathway (AP) and atrial fibrillation (AF) include only short follow-up periods. The aim of this study was to analyze predictors of recurrence of AF in patients after successful RFCA of APs over long term follow-up periods. METHODS Of the 1,007 patients who underwent non-pharmacological treatment of APs (between the years 1993-2008), data of 100 consecutive patients were retrospectively analyzed (75 men, mean age 43.6 ± 14.7), with the longest period of follow-up (mean 11.3 ± 3.5 years) after successful RFCA of AP. In Group 1, there were 72 patients (54 men, mean age 40.66 ± 13.85 years) without documented episodes of AF after RFCA of AP. Group 2 consisted of 28 patients (21 men, mean age 50.79 ± 14.49 years) with AF episodes despite successful elimination of AP. RESULTS In univariate analysis, patients from Group 1 were significantly younger at the time of abla-tion than patients from Group 2 (40.66 ± 13.85 vs. 50.79 ± 14.49 years; p = 0.002), had shorter his¬tory of AF episodes (4.11 ± 4.07 vs. 8.25 ± 7.50 years; p = 0.024) and had less frequently documented atrial tachycardia (AT) prior to ablation (3.39 vs. 20.00% years; p = 0.022). In multivariate analysis, the history of AF in years (p = 0.043), was an independent risk factor for AF recurrences. CONCLUSIONS Older patient age, longer history of AF and AT prior to RFCA of APs identified a sub-group of patients who required additional treatment. In the multivariate analysis, the history of AF in years (p = 0.043) was a risk factor for AF recurrence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of radiofrequency catheter ablation of accessory pathways on the frequency of atrial fibrillation during long-term follow-up

Aims Atrial fibrillation represents a frequent and potentially life-threatening arrhythmia in patients with accessory atrioventricular pathways. Radiofrequency ablation has become the curative treatment of first choice for these patients. Investigations after successful surgical pathway dissection reported an almost complete elimination of paroxysmal atrial fibrillation. However, there are only...

متن کامل

Radiofrequency catheter ablation in the treatment of Wolff-Parkinson-White syndrome

Introduction: Tachyarrhythmias in Wolf Parkinson White (WPW) syndrome, can be a life threatening factor. Antiarrhythmic drug therapy in this syndrome, has not been completely acceptable. Efficacy, safety and economy of Radio Frequency Catheter Ablation (RFCA) in western studies, has made it as the treatment of choice. In the present study, efficacy of RFCA in the ablation of accessory pathway...

متن کامل

Recurrence rate after accessory pathway ablation.

OBJECTIVE To evaluate characteristics of patients and accessory pathways as well as additional technical factors involved in the reappearance of accessory pathway conduction after successful ablation. DESIGN Analysis of recurrences after radiofrequency ablation. SETTING 163 consecutive patients with 167 accessory pathways. SUBJECTS 97 men and 66 women with a mean (SD) age of 36 (14) range...

متن کامل

Catheter-induced mechanical conduction block of right-sided accessory fibers with Mahaim-type preexcitation to guide radiofrequency ablation.

BACKGROUND Accessory pathways originating at the tricuspid annulus that exhibit decremental antegrade conduction properties (Mahaim-type preexcitation) are amenable to radiofrequency (RF) current catheter ablation. However, a reliable and reproducible strategy for mapping and ablation of these fibers is lacking. METHODS AND RESULTS Eleven patients with preexcited atrioventricular tachycardia ...

متن کامل

Radiofrequency endocardial catheter ablation of accessory atrioventricular pathway atrial insertion sites.

BACKGROUND High rates of success using radiofrequency ablation energy have rapidly transformed catheter ablation from an investigational procedure to the nonpharmacological therapy of choice for symptomatic Wolff-Parkinson-White syndrome. Prior studies of radiofrequency accessory pathway ablation were based on a ventricular approach. Risks associated with prolonged arterial catheter manipulatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiology journal

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2017