Modeling the Error of the Medtronic Paradigm Veo Enlite Glucose Sensor
نویسندگان
چکیده
Continuous glucose monitors (CGMs) are prone to inaccuracy due to time lags, sensor drift, calibration errors, and measurement noise. The aim of this study is to derive the model of the error of the second generation Medtronic Paradigm Veo Enlite (ENL) sensor and compare it with the Dexcom SEVEN PLUS (7P), G4 PLATINUM (G4P), and advanced G4 for Artificial Pancreas studies (G4AP) systems. An enhanced methodology to a previously employed technique was utilized to dissect the sensor error into several components. The dataset used included 37 inpatient sessions in 10 subjects with type 1 diabetes (T1D), in which CGMs were worn in parallel and blood glucose (BG) samples were analyzed every 15 ± 5 min Calibration error and sensor drift of the ENL sensor was best described by a linear relationship related to the gain and offset. The mean time lag estimated by the model is 9.4 ± 6.5 min. The overall average mean absolute relative difference (MARD) of the ENL sensor was 11.68 ± 5.07% Calibration error had the highest contribution to total error in the ENL sensor. This was also reported in the 7P, G4P, and G4AP. The model of the ENL sensor error will be useful to test the in silico performance of CGM-based applications, i.e., the artificial pancreas, employing this kind of sensor.
منابع مشابه
Accuracy of a new real-time continuous glucose monitoring algorithm.
BACKGROUND Through minimally invasive sensor-based continuous glucose monitoring (CGM), individuals can manage their blood glucose (BG) levels more aggressively, thereby improving their hemoglobin A1c level, while reducing the risk of hypoglycemia. Tighter glycemic control through CGM, however, requires an accurate glucose sensor and calibration algorithm with increased performance at lower BG ...
متن کاملAccuracy of two continuous glucose monitoring systems: a head-to-head comparison under clinical research centre and daily life conditions
AIMS To assess the accuracy and reliability of the two most widely used continuous glucose monitoring (CGM) systems. METHODS We studied the Dexcom®G4 Platinum (DG4P; Dexcom, San Diego, CA, USA) and Medtronic Paradigm Veo Enlite system (ENL; Medtronic, Northridge, CA, USA) CGM systems, in 24 patients with type 1 diabetes. The CGM systems were tested during 6-day home use and a nested 6-h clini...
متن کاملAnalysis of Glucose Responses to Automated Insulin Suspension With Sensor-Augmented Pump Therapy
OBJECTIVE The advent of sensor-augmented pump therapy with a low-glucose suspend (LGS) function (Medtronic Paradigm Veo System), allowing insulin to be automatically suspended for up to 2 h when sensor glucose falls below a preset threshold, has the potential to reduce the duration of hypoglycemia. In this article, we analyzed blood glucose profiles following a full 2-h insulin suspension activ...
متن کاملPerformance of a predictive algorithm in sensor-augmented pump therapy in the prevention of hypoglycaemia
The Predictive Low Glucose Management (PLGM) system consists of a Medtronic Veo pump, Enlite sensor, MiniLink REAL-Time transmitter, Bluetooth-RF translator and a predictive algorithm operating from a Blackberry smartphone. The system suspended insulin delivery when the pre-set hypoglycaemic threshold of 4.4 mmol/L was predicted to be reached in 30 minutes. The aim of this study was to determin...
متن کاملThe PILGRIM study: in silico modeling of a predictive low glucose management system and feasibility in youth with type 1 diabetes during exercise.
BACKGROUND Predictive low glucose management (PLGM) may help prevent hypoglycemia by stopping insulin pump delivery based on predicted sensor glucose values. MATERIALS AND METHODS Hypoglycemic challenges were simulated using the Food and Drug Administration-accepted glucose simulator with 100 virtual patients. PLGM was then tested with a system composed of a Paradigm(®) insulin pump (Medtroni...