Critical assessment of the claim of a significant difference between the results of measurements of the Coulomb dissociation of 8 B and the 7 Be ( p , γ ) 8 B direct capture reaction ∗

نویسنده

  • Moshe Gai
چکیده

The Coulomb dissociation (CD) of 8B has emerged as a landmark testing ground of the very method of CD for measuring the cross section of the low-energy 7Be(p, γ )8B direct capture (DC) reaction. Recent claims of evidence of slope difference between CD and DC results are critically examined. We include all relevant RIKEN2 data and all previously published DC data, and we examine the extracted so-called average scale-independent slope (b). The parametrization used by the Seattle group to extract the so-called b-slope parameter is also examined at energies above 300 keV. Considering the physical slope (S ′ = dS/dE) above 300 keV, we observe a (1.7σ ) agreement between slopes (S ′) measured in CD and DC above 300 keV. The claim that S17(0) values extracted from CD data are inconsistent and lower than DC results arises from a neglect of substantial systematic uncertainty of low-energy CD data. A consideration of the published CD S17(0) results yields very consistent S17(0) values that agree with most recent DC measurements. The recent correction of the b-slope parameter suggested by Esbensen, Bertsch, and Snover (EBS) was applied to the wrong b slope calculated using part of the RIKEN2 data. When the correct slope of the RIKEN2 data is used, the EBS correction in fact leads to a substantial disagreement between the slopes of the RIKEN2 data and DC data. In spite of an agreement between CD and DC data neither allow for extracting the slope above 300 keV with high accuracy. Uncertainty of the slope (S ′) leads to an additional uncertainty of the extrapolated S17(0). The slope of the astrophysical cross-section factor S17 must be measured with high precision to enable extraction of the d/s ratio and a high-precision extrapolation of S17(0).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

0 Precision Measurements of the 7 Be ( p , γ ) 8 B Reaction With Radioactive Beams and the 8 B Solar Neutrino Flux ∗

The Be(p, γ)B reaction is one of the major source of uncertainties in estimating the B solar neutrino flux and is critical for undertsanding the Solar Neutrino Problem and neutrinos. The main source of uncertainty is the existence of conflicting data with different absolute normalization. Attempts to measure this reaction rate with Be beams are under way by the UConn-LLN collaboration, and we d...

متن کامل

Preprint CNP - 95 / 18 Astrophysical S - factor of the 7 Be ( p , γ ) 8 B reaction from Coulomb dissociation of 8 B ∗

The Coulomb dissociation method to obtain the astrophysical S-factor, S 17 (0), for the 7 Be(p, γ) 8 B reaction at solar energies is investigated by analysing the recently measured data on the breakup reaction 208 Pb(8 B, 7 Be p) 208 Pb at 46.5 MeV/A beam energy. Breakup cross sections corresponding to E1, E2 and M 1 transitions are calculated with a theory of Coulomb excitation that includes t...

متن کامل

Modeling Structural Relationships between Trauma experience and Peritraumatic dissociation in People with Earthquake Trauma Experience: The Mediating Role of experiential avoidance

Introduction: Earthquake trauma has a wide range of psychological consequences in the affected areas. In addition, the role of Peritraumatic dissociation - as one of the consequences of trauma and the shaping factor of psychological problems - is still unknown. Therefore, the aim of the present study was to Modeling Structural Relationships between Trauma experience and Peritraumatic dissociati...

متن کامل

Comparing the Scores of Sequential Organ Failure Assessment and a Proposed Bedside Tool in Patients with Systemic Inflammatory Response Syndrome Admitted to ICU

 Background and purpose: Sequential organ failure assessment (SOFA) is used to assess the severity of the disease and mortality rate in patients admitted to ICU. SOFA requires experiments that are impractical in centers with limited resources. The aim of this study was to compare the diagnostic value of bedside SOFA (b SOFA) and SOFA scores in mortality of ICU patients. Materials and methods: ...

متن کامل

Comparative clinical assessment of two nasolabial hyaluronic acid fillers: A double-blind, randomized controlled trial

Background: Various fillers have been used for the correction of nasolabial folds. This study investigated the efficacy and safety assessment of two hyaluronic acid (HA) fillers on moderate nasolabial folds. Methods: This study randomized 10 volunteers, aged 35 to 49 years, with moderate nasolabial folds. Volunteers received injections of HA A and HA B gels into the right or left skin folds. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006