Assessment of myocardial perfusion and contractile function by inotropic stress Tc-99m sestamibi SPECT imaging and echocardiography for optimal detection of multivessel coronary artery disease.
نویسندگان
چکیده
OBJECTIVE To assess whether inotropic stress myocardial perfusion imaging, echocardiography, or a combination of the two could enhance the detection of multivessel disease, over and above clinical and exercise electrocardiographic data. DESIGN 100 consecutive patients investigated by exercise electrocardiography and diagnostic coronary arteriography underwent simultaneous inotropic stress Tc-99m sestamibi SPECT (MIBI) imaging and echocardiography. MIBI imaging and echocardiographic data were analysed using a 12 segment left ventricular model, and each segment was ascribed to a particular coronary artery territory. The presence of perfusion defects with MIBI imaging or of wall thickening abnormality with echocardiography in at least two coronary artery territories at peak stress was taken as diagnostic of multivessel disease. Arteriographic evidence of > or = 50% stenosis was considered significant. RESULTS 56 patients had multivessel disease. The sensitivity of the combination of MIBI imaging and echocardiography for detecting this was greater than either MIBI imaging or echocardiography alone (82%, 68%, and 68%, respectively; p = 0.005). Clinical and exercise electrocardiographic variables gave an R2 value of 18.2% for predicting multivessel disease. The addition of either MIBI imaging (R2 = 29.2%; p = 0.002) or echocardiography (R2 = 28.8%; p < 0.001) enhanced the detection of multivessel disease, and the inclusion of both had further incremental value (R2 = 34.8%; p = 0.003). Age (p = 0.03), MIBI imaging (p = 0.007), and echocardiography (p = 0.001) were independent predictors of multivessel disease. CONCLUSIONS The assessment of both myocardial perfusion and contractile function by simultaneous inotropic stress MIBI imaging and echocardiography optimises the non-invasive detection of multivessel disease.
منابع مشابه
Filter selection for 99mTc-Sestamibi myocardial perfusion SPECT imaging [Persian]
Myocardial perfusion SPECT imaging with Tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. Though simple and straight forward the results produced by the technique is very much affected by the details being used. One of the main problems with the test, wh...
متن کاملMyocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]
Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...
متن کاملDipyridamole stress echocardiography and ultrasonic myocardial tissue characterization in predicting myocardial ischemia, in comparison with dipyridamole stress Tc-99m MIBI SPECT myocardial imaging.
The purpose of this study was to validate whether dipyridamole stress ultrasonic tissue characterization with cyclic variation of integrated backscatter (CVIBS) compared with dipyridamole stress echocardiography and dipyridamole stress Tc99m-MIBI SPECT myocardial perfusion scintigraphy could predict myocardial ischemia in patients with chronic coronary artery disease. Twenty patients (16 M, 4 F...
متن کاملComparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group
Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...
متن کاملAssessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress: comparison with (99m)Tc-sestamibi SPECT imaging.
BACKGROUND Harmonic power Doppler imaging (HPDI) is a novel technique for assessing myocardial perfusion by contrast echocardiography in humans. The purpose of this study was to compare myocardial perfusion by HPDI with that obtained by (99m)Tc-sestamibi single photon emission computed tomography (SPECT) during rest and pharmacological stress. METHODS AND RESULTS HPDI was performed on 123 pat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 79 3 شماره
صفحات -
تاریخ انتشار 1998