Influence of heart rate, respiration and recipient atrial contraction on pulsed wave transmitral Doppler flow indices in orthotopic heart transplant recipients.
نویسندگان
چکیده
AIMS The study set out to assess the relative contributions of donor heart rate, respiration and recipient atrial contraction on the mean of pulsed wave transmitral Doppler flow indices in orthotopic heart transplant recipients. This would provide information on the theoretical usefulness of pacemaker synchronization of recipient atrial contraction, as well as on the validity of certain strategies used for pulsed wave Dopper analysis of diastolic left ventricular function, which have excluded beats based on recipient atrial contraction timing. METHODS Thirty two consecutive patients undergoing orthotopic heart transplantation in our centre were prospectively studied. The following Doppler indices were analysed: peak early diastolic velocity (E) and its area under the Doppler curve (TVIE), diastolic velocity after donor atrial contraction (A) and its area under the curve (TVIA), the total area under the curve (TVI), the isovolumic relaxation period (IVR), the diastolic filling period, the normalized peak filling rate and the pressure half time. RESULTS Only 81 out of 347 recordings (23%) allowed analysis of the recipient P wave and thus recipient atrial contraction timing, heart rate and the respiration phase in 22 patients for a total of 1579 beats. The isovolumic relaxation period, E, pressure half time and TVIA are not influenced by donor heart rate. For the isovolumic relaxation period, E, TVI and TVIE, respiration contributes as much as recipient atrial contraction timing to beat-to-beat variation. Pressure half time, the diastolic filling period and peak filling rate were not affected by respiration. TVI was not affected by recipient atrial contraction timing. CONCLUSION With respect to analysis of diastolic function, exclusion of beats based on recipient atrial contraction timing is invalid for the isovolumic relaxation period. E, TVI and TVIE, since these are equally influenced by respiration. Since TVI was not affected by recipient atrial contraction timing, pacemaker synchronization of donor and recipient atria is not expected to be useful in patients with left ventricular diastolic dysfunction.
منابع مشابه
Changes in transmitral velocities with heart rate.
Sir, During a study ofchanges in afterload induced by the cold pressor test, Smith et al (1989;61:344-7) recognised a relation between heart rate and transmitral velocities derived from pulsed Doppler recordings. We specifically studied the relation between transmitral velocities and differing RR intervals during exercise and respiration in healthy men.'2We found a clear cut linear change in pe...
متن کاملEffects of diltiazem on left ventricular diastolic behavior in patients with hypertrophic cardiomyopathy: evaluation with exercise pulsed Doppler echocardiography.
To estimate the effects of diltiazem on the left ventricular diastolic abnormalities in patients with hypertrophic cardiomyopathy, transmitral flow velocity during diastole was studied before and immediately after dynamic leg exercise with the pulsed Doppler technique combined with two-dimensional echocardiography. Seventeen patients with hypertrophic cardiomyopathy and 24 apparently healthy me...
متن کاملDoppler tissue imaging for assessing left ventricular diastolic dysfunction in heart transplant rejection.
OBJECTIVE To test the hypothesis that diastolic mitral annular motion velocity, as determined by Doppler tissue imaging and left ventricular diastolic flow propagation velocity, is related to the histological degree of heart transplant rejection according to the International Society of Heart and Lung Transplantation (ISHLT). METHODS In 41 heart transplant recipients undergoing 151 myocardial...
متن کاملTransmitral velocities measured by pulsed Doppler in healthy volunteers: effects of acute changes in blood pressure and heart rate.
The effect of a two minute cold pressor test on transmitral velocities measured by pulsed Doppler was studied in 11 healthy volunteers. Blood pressure increased significantly during cold immersion but peak atrial and peak early diastolic transmitral velocities and their ratio (A:E) were unchanged. There was no correlation between changes in Doppler variables and changes in calculated mean arter...
متن کاملNormal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran
Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal
دوره 18 10 شماره
صفحات -
تاریخ انتشار 1997