Smart infusion technology: a minimum safety standard for intensive care?

نویسندگان

  • Linda J Murdoch
  • Victoria L Cameron
چکیده

There is overwhelming evidence that medication errors present a risk to patients. This risk is highest in the intensive care unit (ICU) setting and even greater when medications are administered via an infusion pump. Standard pumps will not alert for, or prevent, drug calculation, drug unit, button push, or multiple of ten errors when medication delivery data is inputted. However, the literature suggests that smart pumps programmed with hard (unchangeable) limits can significantly reduce drug errors at the point of administration. Staff at St George's Hospital paediatric ICU wanted to implement an infusion pump system that would be immediately effective in reducing medication errors at the point of administration. This article presents an overview of the relevant literature together with clinical examples from the authors' ICU, which demonstrates their experiences with smart pumps. It is the authors' firm belief that smart infusion technology sets a new minimum safety standard for intensive care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intravenous Infusion Safety Initiative: Collaboration, Evidence-Based Best Practices, and “Smart” Technology Help Avert High-Risk Adverse Drug Events and Improve Patient Outcomes

At a 644-bed, tertiary-care, “magnet” system, intravenous (IV) infusion medication errors were determined to present the greatest risk of harm. An IV infusion safety initiative focused on multidisciplinary collaboration, standardization of IV dosing, and medication safety technology. A modular IV infusion safety system was determined to provide the greatest “speed to impact” in reducing harm. I...

متن کامل

Difficulty Using Smart Pump Logs to Recreate a Patient Safety Event: Case Study and Considerations for Pump Enhancements

The authors present a case in which a physical anomaly with an infusion pump resulted in an unforeseen fault that the nurse's attempts to resolve unknowingly exacerbated. This case study presents the first report in the literature to detail the difficulty in recreating a patient safety event using smart pump logs, support server continuous quality improvement (CQI) data, and the drug order entr...

متن کامل

A controlled trial of smart infusion pumps to improve medication safety in critically ill patients.

OBJECTIVE Intravenous medications are vital during inpatient management. Errors associated with the administration of medications through intravenous infusion pumps to critically ill patients can result in adverse drug events. We sought to assess the impact of smart pumps with integrated decision support software on the incidence and nature of medication errors and adverse drug events. DESIGN...

متن کامل

Smart pumps and random safety audits in a Neonatal Intensive Care Unit: a new challenge for patient safety

BACKGROUND Random safety audits (RSA) are a safety tool enabling prevention of adverse events, but they have not been widely used in hospitals. The aim of this study was to use RSAs to assess and compare the frequency of appropriate use of infusion pump safety systems in a Neonatal Intensive Care Unit (NICU) before and after quality improvement interventions and to analyse the intravenous medic...

متن کامل

Perspective of Nurses toward the Patient Safety Culture in Neonatal Intensive Care Units

Background: Infants hospitalized in neonatal intensive care units (NICUs) are often severely ill, highly prone to various diseases, and exposed to complex and prolonged intensive care interventions. Consequently, they are susceptible to the lapses in teamwork and patient safety. Patient safety culture a fundamental step to improve patient safety. The present study aimed to evaluate the perspect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of nursing

دوره 17 10  شماره 

صفحات  -

تاریخ انتشار 2008