SCIENTIFIC REPORT Intraocular pressure associations with refractive error and axial length in children

نویسندگان

  • A J Lee
  • S-M Saw
  • G Gazzard
  • A Cheng
  • D T H Tan
چکیده

Aim: To assess whether intraocular pressure (IOP) is associated with refractive error or axial length in children. Methods: Of subjects from the Singapore Cohort Study of the Risk Factors for Myopia (SCORM), 636 Chinese children aged 9–11 years from two elementary schools underwent non-contact tonometry, cycloplegic autorefraction, and Ascan biometry during 2001. For analyses, refractive error was categorised into four groups; hypermetropia (spherical equivalent refraction (SE) >+1.0D), emmetropia (20.5D,SE,+1.0D), low myopia (23.0D,SE(20.5D) and high myopia (SE(23.0D). Results: Of the 636 children examined, 50.6% were male. The mean IOP was 16.6 (SD 2.7) mm Hg. There were no significant IOP differences between low (mean IOP = 16.4 (2.8) mm Hg) or high myopes (16.7 (2.5) mm Hg) and emmetropes (16.7 (2.9) mm Hg), p = 0.57. IOP was not correlated with spherical equivalent refraction (Spearman correlation, r = 0.009) or axial length (r = 0.030). In regression analyses adjusting for diastolic blood pressure, neither spherical equivalent (regression coefficient = 0.014) nor axial length (regression coefficient = 0.027) were significantly associated with IOP. Conclusion: These findings do not support an association between IOP and refractive error or axial length in children. This questions postulated roles of IOP in the pathogenesis of myopia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular pressure associations with refractive error and axial length in children.

AIM To assess whether intraocular pressure (IOP) is associated with refractive error or axial length in children. METHODS Of subjects from the Singapore Cohort Study of the Risk Factors for Myopia (SCORM), 636 Chinese children aged 9-11 years from two elementary schools underwent non-contact tonometry, cycloplegic autorefraction, and A-scan biometry during 2001. For analyses, refractive error...

متن کامل

The Correlation between Glucose and Lipid Biomarkers Variations with biometric characteristics and Intraocular Pressure Changes during Ramadan Fasting

Introduction: The aim of present study was to assess the correlation between glucose and lipid biomarkers variations with biometric characteristics and intraocular pressure changes following Ramadan fasting. Methods: A total of 100 healthy fasting volunteers were enrolled in the study. Of them, 89 subjects completed the study with respect to inclusion and exclusion criteria. Right eye ocular ax...

متن کامل

Factors related to axial length elongation and myopia progression in orthokeratology practice

PURPOSE To investigate which baseline factors are predictive for axial length growth over an average period of 2.5 years in a group of children wearing orthokeratology (OK) contact lenses. METHODS In this retrospective study, the clinical records of 249 new OK wearers between January 2012 and December 2013 from the contact lens clinic at the Eye and ENT Hospital of Fudan University were revie...

متن کامل

A Clinical Study on the Correlation Between Axial Length, Intraocular Pressure and Central Corneal Thickness in Myopic Eyes

Introduction: Myopia or short sightedness, is that form of refractive error wherein parallel rays of light come to a focus in front of the sentient layer of the retina when the eye is at rest; the eye is thus relatively too large, and the condition is the opposite to that of hypermetropia. Aims and objectives of the research were to find out whether there is a correlation between axial length, ...

متن کامل

Ocular risk factors for choroidal neovascularization in pathologic myopia.

UNLABELLED PURPOSE. To identify the risk factors for development of myopic choroidal neovascularization (mCNV), a major cause of visual impairment. METHODS. Enrolled in the study were 23 consecutive patients with bilateral high myopia (axial length, > or =26.5 mm or refractive error, < or =8 D) and unilateral newly developed mCNV who presented to the Myopia Clinic, Osaka University Hospital. Sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003