Proximal Femur Locking Plate for Sub-Trochanteric Femur Fractures: Factors Associated with Failure

نویسندگان

  • Akbar Zubairi
  • Rizwan Haroon Rashid
  • Marij Zahid
  • Pervaiz Mahmood Hashmi
  • Shahryar Noordin
چکیده

INTRODUCTION Proximal femur locking compression plates (PF-LCP) have gained popularity since their inception due to superior biomechanical stability and durability but clinical experience has shown conflicting results including implant failure. OBJECTIVE To study the incidence of implant failure in patients with sub-trochanteric fractures managed with proximal femoral locking compression plate and identify potential risk factors associated with the failure. MATERIALS & METHODS Fifty patients with sub-trochanteric fractures, operated upon with titanium PF-LCP were included in the study from January 2012 to December 2014. These plates were of two designs including one five 5.0 mm proximal locking screws (implant A) and other with three 6.5 mm proximal locking screws (implant B). Fractures were classified according to AO/OTA and Seinsheimer classification. Patients had regular follow-up visits for at least a year, allowing for clinical and radiological assessment of union and implant-related complications. RESULTS A total of 13 out of 50 (26%) plates failed of which 7 were implant fractures, 3 screw breakage and 3 screw cut outs. 70% of the failures occurred in elderly females. Overall implant failure was significantly more common in patients >50 years (p 0.04). Comparing the two different designs of implants used, implant A was more likely to fail at a plate screw density of 0.8 or more (p 0.02), whereas implant B was associated with significant failure when less than 4 proximal screws were used (p 0.03). CONCLUSION This study revealed a high failure rate (26%) of this implant. Attention to the neck shaft angle difference, number of proximal screws and plate screw density may help reduce failure rates, particularly in elderly osteoporotic females.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Unstable Trochanteric Femur Fractures: Proximal Femur Nail Versus Proximal Femur Locking Compression Plate.

Unstable trochanteric femur fractures are common fractures that are difficult to manage. We conducted a prospective study to compare functional outcomes and complications of 2 different implant designs, proximal femur nail (PFN) and proximal femur locking compression plate (PFLCP), used in internal fixation of unstable trochanteric femur fractures. On hospital admission, 48 patients with unstab...

متن کامل

Our experience of management of sub trochanteric fractures of femur by proximal femoral nail

The sub trochanteric zone of the femur is the area extending up till 5 cm distally from the inferior border of the lesser trochanter or the junction of the proximal third and middle third of the femoral shaft. Fracture patterns presenting major displacement in this area are considered sub trochanteric fractures despite their proximal or distal extension. 1 High biomechanical stress concentratio...

متن کامل

Reversed anatomic distal femur locking plate for periprosthetic hip fracture fixation.

The incidence of femoral fracture on hip prosthesis is increasing. Plate fixation is the method of choice when the prosthesis is stable. In fracture with proximal extension, the quality of the bone fixation is critical and, despite the development of anatomic plates, may be endangered when there are too few proximal screws. To resolve this issue, we recommend using a reversed LCP™ anatomic dist...

متن کامل

Morphology and fixation pitfalls of a highly unstable intertrochanteric fracture variant.

PURPOSE To describe a variant of intertrochanteric fracture not well-characterised in the existing classification systems. METHODS 10 women and 2 men aged 59 to 98 (median, 80) years with intertrochanteric fractures characterised by a low intertrochanteric fracture, a basicervical fracture fragment, and a thin or fractured lateral wall with greater trochanteric comminution were reviewed. RE...

متن کامل

A Prospective Study to Evaluate the Management of Sub-trochanteric Femur Fractures with Long Proximal Femoral Nail

Introduction: Sub-trochanteric fractures of the femur remains one of the most challenging fractures faced by orthopaedic surgeons. This study was done to analyse the management and complications of sub-trochanteric fractures using long proximal femoral nail (PFN). Materials and Methods: This was a prospective study of 50 patients with sub-trochanteric fractures of femur who were treated with lo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017