Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer.

نویسندگان

  • René W M Underberg
  • Frank J Lagerwaard
  • Johan P Cuijpers
  • Ben J Slotman
  • John R van Sörnsen de Koste
  • Suresh Senan
چکیده

PURPOSE Hypofractionated stereotactic radiotherapy (SRT) for Stage I non-small-cell lung cancer requires that meticulous attention be paid toward ensuring optimal target definition. Two computed tomography (CT) scan techniques for defining internal target volumes (ITV) were evaluated. METHODS AND MATERIALS Ten consecutive patients treated with SRT underwent six "standard" rapid multislice CT scans to generate an ITV(6 CT) and one four-dimensional CT (4DCT) scan that generated volumetric datasets for 10 phases of the respiratory cycle, all of which were used to generate an ITV(4DCT). Geometric and dosimetric analyses were performed for (1) PTV(4DCT), derived from the ITV(4DCT) with the addition of a 3-mm margin; (2) PTV(6 CT), derived from the ITV(6 CT) with the addition of a 3-mm margin; and (3) 6 PTV(10 mm), derived from each separate GTV(6 CT), to which a three-dimensional margin of 10 mm was added. RESULTS The ITV(4DCT) was not significantly different from the ITV(6 CT) in 8 patients, but was considerably larger in 2 patients whose tumors exhibited the greatest mobility. On average, the ITV(6 CT) missed on average 22% of the volume encompassing both ITVs, in contrast to a corresponding mean value of only 8.3% for ITV(4DCT). Plans based on PTV(4DCT) resulted in coverage of the PTV(6 CT) by the 80% isodose in all patients. However, plans based on use of PTV(6 CT) led to a mean PTV(4DCT) coverage of only 92.5%, with a minimum of 77.7% and 77.5% for the two most mobile tumors. PTVs derived from a single multislice CT expanded with a margin of 10 mm were on average twice the size of PTVs derived using the other methods, but still led to an underdosing in the two most mobile tumors. CONCLUSIONS Individualized ITVs can improve target definition for SRT of Stage I non-small-cell lung cancer, and use of only a single CT scan with a 10-mm margin is inappropriate. A single 4D scan generates comparable or larger ITVs than are generated using six unmonitored rapid CT scans, a finding related to the ability to account for all respiration-correlated mobility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The colossal circumvention of the lung lesion during lung stereotaxy

This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...

متن کامل

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

A Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer

Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...

متن کامل

Accuracy of Breath-hold CT in Treatment Planning for Lung Stereotactic Ablative Radiotherapy

PURPOSE The objectives of this study are (1) to measure concordance of tumor position on breath-hold (BH) computed tomography (CT) scans relative to the natural tumor path during free breathing (FB) and (2) to evaluate the benefits of the breathing monitoring device Abches (Apex Medical, Tokyo) for stereotactic ablative radiotherapy (SABR) treatment planning. METHODS In 53 lung cancer patient...

متن کامل

The Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose

Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...

متن کامل

Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer

BACKGROUND 4-dimensional CT (4DCT) scans are increasingly used to account for mobility during radiotherapy planning. As variations in respiratory patterns can alter observed motion, with consequent changes in the generated target volumes, we evaluated the reproducibility of 4D target volumes generated during repeat uncoached quiet respiration. METHODS A retrospective analysis was performed on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 60 4  شماره 

صفحات  -

تاریخ انتشار 2004