A model for wetting and evaporation of a post-blink precorneal tear film.

نویسندگان

  • Katlyn N Winter
  • Daniel M Anderson
  • Richard J Braun
چکیده

We examine a fluid dynamic model for the evolution of a precorneal tear film that includes evaporation of the aqueous layer and a wetting corneal surface. Our model extends previous work on the break-up time for a post-blink tear film to include a more realistic model for evaporation. The evaporation model includes the effects of conjoining pressure and predicts the existence of an equilibrium adsorbed fluid layer that serves as a model for a wetting corneal surface/mucin layer. The model allows the prediction of dewetting rates that are compared with experimental measurements. By choosing an expected thickness where evaporation and conjoining pressure balance, we obtain qualitative agreement for the opening rate with in vivo observations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modelling drainage of the precorneal tear film after a blink.

We study the drainage of the precorneal tear film in humans. A fluid dynamic model for the drainage of the aqueous layer is developed that includes the effects of evaporation and gravity. The model may be reduced to a single nonlinear partial differential equation for the thickness of the aqueous layer. The equation is solved numerically and accurate times for film rupture are obtained for phys...

متن کامل

A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: viscoelastic increases tear film stability.

PURPOSE To develop a safe, noninvasive, noncontact, continuous in vivo method to measure the dehydration rate of the precorneal tear film and to compare the effectiveness of a viscoelastic agent in maintaining the precorneal tear film to that of a balanced salt solution. METHODS Software was designed to analyze the corneal reflection produced by the operating microscope's coaxial illumination...

متن کامل

Evaporation rate of water from the precorneal tear film and cornea in the rabbit.

A technique for the study of evaporation from the precorneal and cornea! surfaces has been developed. Evaporation from the superficial lipid layer (SLL) has been measured to be 10.1 x 10~ Gm.cm.^secr When this lipid layer is removed, evaporation increases around fourfold. Evaporation from the dry epithelial surface occurs at a rate of 1.8 x JO" Gm.cmr^secr After the epithelium is removed, a twe...

متن کامل

Dry eye, blinking, and blepharospasm.

The primary purpose of the eyelids is to ensure corneal integrity. An important component of this protective function is maintaining the corneal tear film. Blink characteristics can determine tear film stability. Increasing blink amplitude thickens the lipid layer that overlies the aqueous layer of the tear film. This thickening reduces evaporation of the aqueous layer. Because each blink refor...

متن کامل

Effect of water-in-oil microemulsions and lamellar liquid crystalline systems on the precorneal tear film of albino New Zealand rabbits

The aim of this study is to investigate the effect of phase transition water-in-oil (w/o) microemulsions (ME) and liquid crystalline systems (LC) on the precorneal tear film (PCTF). The study used six albino NZ rabbits and monitored the integrity and stability of the PCTF before and after instillation of test formulations. The effects were evaluated by assessment of the PCTF lipid layer using i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Mathematical medicine and biology : a journal of the IMA

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2010