Clinical outcomes after subpectoral biceps tenodesis with an interference screw.

نویسندگان

  • Augustus D Mazzocca
  • Mark P Cote
  • Cristina L Arciero
  • Anthony A Romeo
  • Robert A Arciero
چکیده

BACKGROUND Subpectoral biceps tenodesis with an interference screw has been shown to be an effective procedure from both an anatomic and biomechanical perspective. There have been no clinical outcome data on this procedure to date. HYPOTHESIS Subpectoral biceps tenodesis is an effective procedure in eliminating biceps tendinosis symptoms. STUDY DESIGN Case series; Level of evidence, 4. METHODS Patients who underwent subpectoral biceps tenodesis with a minimum follow-up of 1 year were evaluated using a battery of clinical outcome measures, biceps apex difference, and pain scores. A diagnosis of biceps tendinosis was made using a specific diagnostic protocol coupled with observation of biceps tendon fraying and increased erythema on dry arthroscopy. RESULTS Between November 2002 and August 2005, 50 patients underwent subpectoral biceps tenodesis. Complete follow-up examinations were performed in 41 of 50 (82%). There were 16 women and 25 men (mean age, 50 years). Follow-up averaged 29 months (range, 12-49 months). The mean scores were 86, Rowe; 81, American Shoulder and Elbow Surgeons (ASES); 9, Simple Shoulder Test (SST); 87, Constant Murley; and 84, Single Assessment Numeric Evaluation (SANE). There was 1 failure as demonstrated by pull-out of the tendon from the bone tunnel resulting in a "Popeye" deformity on physical examination. The mean value for biceps apex distance was 0.15 cm, with 35 of 41 patients demonstrating no difference on physical examination. Twenty-three of 41 patients had complete preoperative and postoperative examinations. All clinical outcome measures demonstrated a statistically significant improvement at follow-up when compared with the preoperative scores. Thirty-one patients had identified lesions of the rotator cuff at time of arthroscopy. The mean ASES score in patients without rotator cuff lesion (89.2 +/- 10.3) was significantly greater than the mean ASES for those with rotator cuff lesion (78.0 +/- 21.0) (P = .0324). The mean SST score in patients without rotator cuff lesion (10.6 +/- 1.5) was significantly greater than the mean ASES score for those with rotator cuff lesion (8.8 +/- 2.7) (P = .0132). CONCLUSION Subpectoral biceps tenodesis with an interference screw is a viable treatment option for patients with symptomatic biceps tendinosis. Anterior shoulder pain and biceps symptoms were resolved with this technique. Patients with coexistent rotator cuff lesion had less favorable outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interference Screw vs. Suture Anchor Fixation for Open Subpectoral Biceps Tenodesis: Does it Matter?

BACKGROUND Bioabsorbable interference screw fixation has superior biomechanical properties compared to suture anchor fixation for biceps tenodesis. However, it is unknown whether fixation technique influences clinical results. HYPOTHESIS We hypothesize that subpectoral interference screw fixation offers relevant clinical advantages over suture anchor fixation for biceps tenodesis. STUDY DES...

متن کامل

Biomechanical comparison of intramedullary cortical button fixation and interference screw technique for subpectoral biceps tenodesis.

PURPOSE The purpose of this study was to biomechanically evaluate a new technique of intramedullary cortical button fixation for subpectoral biceps tenodesis and to compare it with the interference screw technique. METHODS We compared intramedullary unicortical button fixation (BicepsButton; Arthrex, Naples, FL) with interference screw fixation (Bio-Tenodesis screw; Arthrex) for subpectoral b...

متن کامل

Biomechanical evaluation of subpectoral biceps tenodesis: dual suture anchor versus interference screw fixation.

BACKGROUND Subpectoral biceps tenodesis has been reliably used to treat a variety of biceps tendon pathologies. Interference screws have been shown to have superior biomechanical properties compared to suture anchors; although, only single anchor constructs have been evaluated in the subpectoral region. The purpose of this study was to compare interference screw fixation with a suture anchor co...

متن کامل

Humeral fracture following subpectoral biceps tenodesis in 2 active, healthy patients.

Pathology involving the long head of the biceps tendon is a common and significant cause of shoulder pain. For active patients with refractory biceps tendinosis, tenodesis of the tendon to either soft tissue or the humerus is the preferred surgical treatment. Subpectoral biceps tenodesis to the humeral diaphysis with an interference screw has been gaining popularity as an effective method for t...

متن کامل

Complications associated with subpectoral biceps tenodesis: low rates of incidence following surgery.

BACKGROUND Tenodesis of the long head of the biceps tendon is a common procedure used to alleviate pain caused by instability or inflammation of the tendon. The purpose of this study is to report on the incidence and types of complications following an open subpectoral biceps tenodesis (OBT) procedure. HYPOTHESIS Our hypothesis was that the rate of adverse events after OBT was low. METHODS ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of sports medicine

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 2008