Effect of applying positive pressure with or without endotracheal suctioning during extubation: a laboratory study.

نویسندگان

  • Mauro F Andreu
  • Iris G Salvati
  • Mariana C Donnianni
  • Belén Ibañez
  • Mariana Cotignola
  • Marco Bezzi
چکیده

BACKGROUND During invasive mechanical ventilation, secretions accumulate in the subglottic space; consequently, there is a risk of aspiration of these secretions into the airway during cuff deflation and extubation. To minimize this risk, 2 extubation methods are used. The first consists of introducing a suction catheter into the endotracheal tube (ETT) and the trachea. After initiating suctioning, the cuff is deflated and the ETT is removed together with the suction catheter. The second technique involves applying positive pressure to the ETT using a resuscitation bag. Once the manual breath is delivered, the ETT cuff is deflated and the ETT is removed without suction. The aim of this laboratory study is to determine the existence and magnitude of differences in leak volume during cuff deflation and extubation using various combinations of positive pressure with or without endotracheal suctioning. METHODS An ETT connected to a ventilator was placed in a model trachea. Colored water was instilled in the space above the cuff. To measure the leak volume, a collection chamber was attached to the distal end of the model. Nine procedures were defined, based on the delivery of different positive pressure levels with or without endotracheal suctioning during extubation. The volume of leakage, in milliliters, was the unit of analysis. Procedures yielding values lower than 1 mL were assessed by the Friedman test, and a P value of less than .05 was considered significant. Post hoc comparisons were performed with a Wilcoxon test, followed by a Bonferroni correction. RESULTS The application of CPAP 15, pressure support ventilation (PSV)15/10, and PSV 20/5 produced 0.4, 0.2, and 0.1 mL of leak volume, respectively. Statistically significant differences were found between CPAP 15 and PSV 15/10 (P = .003) and between CPAP 15 and PSV 20/5 (P = .01), but not between PSV 15/10 and PSV 20/5 (P = .30). The addition of suctioning increased leak volume, with statistically significant differences between CPAP 15 and CPAP 15 + endotracheal suctioning (P = .001) and between PSV 15/10 and PSV 15/10 + endotracheal suctioning (P = .001). CONCLUSIONS Endotracheal suctioning during cuff deflation and extubation produced greater leakage. Application of CPAP 15, PSV 15/10, and PSV 20/5 resulted in the lowest leak values, with the best results being obtained with the use of PSV 15/10 and PSV 20/5.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تأثیر فشردن قفسه سینه در زمان بازدم قبل از ساکشن داخل تراشه بر تبادل گازهای خون شریانی بیماران تحت تهویه مکانیکی

  Background & Aim : Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients under mechanical ventilation. Chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. This study was carried out to...

متن کامل

تأثیر بازآموزی ساکشن لوله داخل تراشه برای پرستاران، بر تغییرات فشارخون بیماران بستری در بخش مراقبت ویژه

Background & Aim: Endotracheal suctioning (ETS) is a common invasive nursing procedure. Hemodynamic parameters changes during and after the procedure. If appropriate strategies do not be applied during the ETS, hemodynamic changes can be significant and life threatening in critically ill patients. The purpose of this study was to assess the effect of education of endotracheal suctioning on pati...

متن کامل

Neonatal Intensive Care Units Nurses’ Attitude Toward Advantages and Disadvantages of Open vs Closed Endotracheal Suction

BACKGROUND The vital issue of protecting the airway and maintaining ventilation in preterm infants makes tracheal suctioning an important procedure. The decision to use closed or open endotracheal suction method depends on the clinical status of infants and the nurses' skills and preferences. OBJECTIVES The current study aimed to compare the two methods based on the perceptions of the nurses ...

متن کامل

The effect of dexmedetomidine on the hemodynamic responses of endotracheal extubation and sedation level in recovery after cholecystectomy

Background: Emergence from general anesthesia and removing of tracheal tube can be associated with coughing, agitation, and hemodynamic disturbances. Dexmedetomidine is an alpha two adrenoceptor agonist that has effective sedation with less cardiovascular unstability and respiratory depression and may be useful for extubation and prevention of hemodynamic response during tracheal tube removing....

متن کامل

A Comparison of the effect of open and closed endotracheal suctioning on hemodynamic status of patients in the ICU

Background: If not done properly, suction causes complications such as hypoxia, cardiac arrhythmias or even death. Suction is being used in most hospital wards. Closed Suction appears to have fewer side effects, although studies have reported dissimilar results. Aim: The aim of this study was to compare the effect of open (control) with closed (test) endotracheal suctioning on patients’ Hemodyn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 59 12  شماره 

صفحات  -

تاریخ انتشار 2014