Successful thrombolytic therapy for stuck mitral mechanical valve.

نویسندگان

  • Hamoud Y Obied
  • Mohammed F Ibrahim
  • Bendehiba S Latroche
  • Maya M Mroue
چکیده

Thrombosis of a mechanical prosthetic valve is a serious and fortunately it is a rare complication of cardiac valve replacement. We present a case of prosthetic mechanical valve On-X 31/33 mm thrombosis thrombus size 8 x 14 mm on a mitral position, which was treated with a successful intravenous thrombolytic therapy of streptokinase infusion over 10 hours repeated twice with no complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Thrombolysis is an effective and safe therapy in stuck bileaflet mitral valves in the absence of high-risk thrombi.

OBJECTIVES We sought to evaluate the effectiveness and safety of thrombolytic therapy in stuck mitral bileaflet heart valves in the absence of high-risk thrombi. BACKGROUND Current recommendations for the thrombolytic treatment of stuck prosthetic mitral valves are partially based on older valve models and inclusion of patients in whom high-risk thrombi were either ignored or not sought for. ...

متن کامل

Successful thrombolysis of mitral valve prosthesis by streptokinase during pregnancy.

A 37 year old female patient presented with the clinical picture of pulmonary edema while pregnant (13 weeks). Eight years earlier she underwent mitral valve replacement because of rheumatic mitral incompetence using bileaflet StJude prosthesis. Her oral anticoagulation maintenance therapy (Coumadin) was discontinued by her physician and shifted to subcutaneous unfractionated heparin 10 days pr...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Successful thrombolysis of a thrombosed prosthetic mitral valve using a synthetic tissue plasminogen activator: a case report

INTRODUCTION Prosthetic valve thrombosis is a rare but life-threatening condition that requires careful evaluation and prompt treatment. While surgical intervention remains the gold standard, thrombolytic therapy is now emerging as a potential substitute. Various thrombolytic treatments including streptokinase, urokinase and recombinant tissue plasminogen activators have been reported with vari...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Saudi medical journal

دوره 30 7  شماره 

صفحات  -

تاریخ انتشار 2009