Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure.
نویسندگان
چکیده
PURPOSE To determine changes in topographical thickness of the epithelium and total cornea after hydrogel (2-hydroxyethyl methacrylate; HEMA or soft lens) and PMMA rigid contact lens wear with eyes closed, as measured by optical coherence tomography (OCT). METHODS Epithelial and total corneal thickness in 18 neophyte eyes was measured with OCT at intervals of 10 degrees across a 10-mm zone of the horizontal meridian of the cornea, before and after 3 hours of soft and rigid contact lens wear with the eye closed. These measurements were repeated 20 minutes after removal of the lenses. RESULTS Lens type, time, and location were found to be significant main influences (P < 0.0001) on corneal swelling in patched eyes, by three-way ANOVA, and there was a significant three-way interaction among lens type, time, and location (F((16,272)) = 1.78, P = 0.033). However, there was no significant main effect and interaction of epithelial thickness (F((16, 272)) = 0.33, P = 0.99). Immediately after removal of the lenses, total corneal thickness in the horizontal meridian was significantly greater with both soft and PMMA lenses (P < 0.001) at each location with each lens, compared with the baseline measurements. With both lenses, the increase in actual thickness and percentage of corneal swelling at the center was greater than at each peripheral point (excluding the first 10 degrees points; P < 0.005). HEMA lenses caused greater corneal swelling than the PMMA lenses at each location immediately after removal of the lenses (P < 0.005). CONCLUSIONS This study shows that corneal swelling is dependent on lens type and corneal location when eyes are closed, but epithelial thickness across the horizontal corneal meridian does not change during lens wear with eyes closed. OCT is an efficient method of measuring topographical corneal and epithelial thickness in response to contact lens wear.
منابع مشابه
Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction.
PURPOSE To investigate topographical thickness changes of the epithelium and total cornea measured with optical coherence tomography (OCT) after overnight wear of rigid gas-permeable lenses. METHODS Reverse geometry design CRT (Dk=100) rigid (test) lenses (Paragon Vision Sciences, Mesa, AZ) were randomly fitted on one eye of each of 20 neophyte subjects (mean age, 24.6 +/- 2.7 years) and the ...
متن کاملEffects of eyelid closure and disposable and silicone hydrogel extended contact lens wear on rabbit corneal epithelial proliferation.
PURPOSE To examine the rabbit corneal epithelial cell proliferation rate after extended wear of disposable or silicone hydrogel contact lenses or prolonged eyelid closure. METHODS One randomly chosen eye of 40 New Zealand White rabbits was assigned to silicone hydrogel contact lens wear (n = 15, SH), disposable hydrogel contact lens wear (n = 6, DH), eyelid suturing (n = 15, SUT), or no inter...
متن کاملEpithelial morphological response to soft hydrogel contact lenses.
Hydrogel (HEMA) contact lenses of increased thickness were worn by owl monkeys (Aotus tivergatus) under open and closed eye conditions to study ultrastructurally the corneal epithelial response to increased stress. The 0.07 mm thick lens with a calculated Dk/L of 4.2-2.2 caused an epithelial thinning without oedema. This thinning was due to a loss of superficial cells and a flattening of the re...
متن کاملCorneal swelling response to contact lenses worn under extended wear conditions.
Corneal thickness changes were monitored in ten subjects (1) over a 36-hour period without contact lens wear and (2) during 7 days continuous wear of three types of hydrogel contact lenses of different back vertex powers. Measured on awakening, the mean overnight central corneal edema without lenses was 3.0% ± 1.2%. With the lenses used in this study, the mean overnight corneal swelling over th...
متن کاملDifferences between overnight and long-term wear of orthokeratology contact lenses in corneal contour, thickness, and cell density.
PURPOSE To investigate changes in corneal topography and morphology in human eyes wearing orthokeratology (OK) lenses for overnight and over a 5-year period. MATERIALS AND METHODS Fifty-six adults with moderate myopia were assigned to 2 groups based on age matching: 5-year lens wear (n = 26, 51 eyes) and 1-night lens wear (n = 30, 60 eyes). All subjects wore reverse-geometry OK lenses with th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2003