Distribution of Phase Errors in Uhf Position Location System
نویسندگان
چکیده
SiO,/Si,NJSiO, dielectric layer for memory capacitor'. IEDM tech dig., 1984, pp. 17S176 3 CHARMET, I. c., and DE GE"ES, P. G. : 'Ellipsometric formulas for an inhomogeneous layer with arbitrary refractive index profile', J . Opt. Soc. Am., 1983,73, p. 1977 4 HO, J. H., LEE, c. L., and LEI, T. F.: 'Error reduction in the ellipsometric measurement on thin transparent film', Solid-state Electron., 1988, 31, p. 1321 2 WATANABE, T., MENJOH, A., ISHIKAWA, M., and KUMAGAI, I.: 'Stacked
منابع مشابه
Prevention of diagnostic errors in position of conus medullaris in adult patients
Background and aims: Finding the safe location of spinal cord for cerebrospinal fluid (CSF) during surgical procedures is very important due to its various nature for each patient as well as its potential peripheral nervous system hazards. The aim of this study was to find the relationship between the location of conus medullaris (CM) and gender, age and body mass index (BMI) in order to minimi...
متن کاملGyroscope Drift Error Analysis in the Position-Independent Navigation Algorithm of a stable platform Inertial System
This paper deals with analyzing gyroscope drift error in the position-independent navigation algorithm of a stable platform inertial system. Most of the stable platform navigation algorithms proposed in the literature have drawbacks of estimating position rates for alignment commands. Not only the estimating position rates are the basic source of position errors, but they also make the alignmen...
متن کاملبررسی عملکرد پروبهای UHF در آشکارسازی تخلیه جزئی در ترانسفورماتورهای فشار قوی
Recently, UHF partial discharge (PD) detection on power transformers attracts lots of attentions. For the transformers already installed in power network, the UHF signals can be captured only by UHF probes installed through oil drain valve. Although UHF probes are commercially produced, there are a lot of missing information on characteristics and features of these probes for PD detection. In t...
متن کاملFault Location in Active Distribution Networks Using Improved Whale Optimization Algorithm
To realize the self-healing concept of smart grids, an accurate and reliable fault locator is a prerequisite. This paper presents a new fault location method for active power distribution networks which is based on measured voltage sag and use of whale optimization algorithm (WOA). The fault induced voltage sag depends on the fault location and resistance. Therefore, the fault location can be f...
متن کاملLEAK DETECTION IN WATER DISTRIBUTION SYSTEM USING NON-LINEAR KALMAN FILTER
Leakage detection in water distribution systems play an important role in storage and management of water resources. Therefore, to reduce water loss in these systems, a method should be introduced that reacts rapidly to such events and determines their occurrence time and location with the least possible error. In this study, in order to determine position and amount of leakage in distribution ...
متن کامل