OBJECTIVES/HYPOTHESIS Scaffold-free cartilage has been used to engineer biocompatible and mechanically stable neotracheas in vivo. The purpose of this animal study was to determine if neotracheal constructs, implanted paratracheally, could successfully be used for segmental tracheal reconstruction. STUDY DESIGN Animal study. METHODS Culture-expanded auricular rabbit chondrocytes were used to engineer scaffold-free cartilage sheets. Cartilage and a strap muscle flap were wrapped around a tube and implanted paratracheally. At 12 to 14 weeks postimplantation neotracheas were used to reconstruct 20 mm tracheal defects. Surgical technique was modified several times in an attempt to decrease the amount of neotracheal obstruction and fibrosis. In one of the six rabbits, neotrachea with its intact strap muscle flap was dropped into the defect followed by an end-to-end anastomosis; in two animals the muscle flap was partially, and in one rabbit completely removed. In two animals the muscle flap was partially removed, the tube reinserted, and the construct reimplanted for 5 weeks to allow formation of a fibrous lining over the exposed cartilage followed by tracheal reconstruction. RESULTS All implants developed into vascularized and mechanically sound neotracheas. Following reconstruction, none of the animals showed immediate signs of respiratory distress; however, one died after 24 hours due to extensive endotracheal muscle flap edema, whereas rabbits who had undergone partial or complete muscle flap removal survived up to 39 days before developing cicatricial stenosis. CONCLUSIONS Tissue-engineered neotracheas proved to have excellent biocompatibility and stability to function under physiologic conditions, but lacked adequate endotracheal lining resulting in neotracheal stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Autologous Cricoid Cartilage as a Graft for Airway Reconstruction in an Emergent Technique - A Case Report

Introduction: Laryngotracheal stenosis can be caused after traumatic injuries to the neck from the subglottic larynx to the trachea. Patients with laryngotracheal stenosis often need a tracheotomy and occasionally may become tracheotomy dependent. Different procedures have been described for the management of these lesions. Management options include techniques of endoscopic dilation, laser res...

متن کامل

Tissue Engineering of the Trachea: What is the Hold-up?

Tissue-engineering of the trachea is called for based on the clinical consequences of airway pathology. Recent years have witnessed various reports from the tissueengineering field including a few cases of clinical patients receiving an engineered airway. Multiple fields have accelerated in parallel with the concept of tissue decellularization, isolation of stem cells and possible insights in t...

متن کامل

The first tissue-engineered airway transplantation: 5-year follow-up results.

BACKGROUND In 2008, the first transplantation of a tissue-engineered trachea in a human being was done to replace an end-staged left main bronchus with malacia in a 30-year-old woman. We report 5 year follow-up results. METHODS The patient was followed up approximately every 3 months with multidetector CT scan and bronchoscopic assessment. We obtained mucosal biopsy samples every 6 months for...

متن کامل

A vascularized tissue-engineered trachea with ectopic pedicled muscle flap

Objectives: Surgical treatment of segment tracheal reconstruction longer than 6 cm needs trachea substitutes, tissue engineering can provide alternatives for tracheal reconstruction. Constructs with blood supply are preferred for tracheal replacement. Here we describe an approach for engineering of vascularized trachea with ectopic pedicled muscle flap. Methods: Poly (L-lactic-co-glycolic acid)...

متن کامل

Assessment of the mechanics of a tissue-engineered rat trachea in an image-processing environment

OBJECTIVES Despite the recent success regarding the transplantation of tissue-engineered airways, the mechanical properties of these grafts are not well understood. Mechanical assessment of a tissue-engineered airway graft before implantation may be used in the future as a predictor of function. The aim of this preliminary work was to develop a noninvasive image-processing environment for the a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Laryngoscope

دوره 119 11  شماره 

صفحات  -

تاریخ انتشار 2009