Patient-prosthesis mismatch in patients treated with transcatheter aortic valve implantation – predictors, incidence and impact on clinical efficacy. A preliminary study
نویسندگان
چکیده
Introduction Patient-prosthesis mismatch (PPM) is relatively frequent after surgical aortic valve replacement (SAVR) and negatively impacts prognosis. Aim We sought to determine the frequency and clinical effects of PPM after transcatheter aortic valve implantation (TAVI). Material and methods Overall, 238 patients who underwent TAVI were screened. Moderate PPM was defined as indexed effective orifice area (EOAi) between 0.65 and 0.85 cm2/m2, and severe PPM as < 0.65 cm2/m2. All-cause mortality and the Valve Academic Research Consortium 2 (VARC-2) defined composite of clinical efficacy at 1 year were the primary endpoints. Results Finally, 201 patients were included (mean age: 79.6 ±7.4 years, 52% females). The femoral artery served as the delivery route in 79% and most of the prostheses were self-expanding (68%). Any PPM was present in 48 (24%) subjects, and only 7 (3.5%) had severe PPM. Body surface area (BSA) independently predicted any PPM (OR = 16.9, p < 0.001) whereas post-dilation tended to protect against PPM (OR = 0.46, p = 0.09). All-cause mortality was similar in patients with moderate or severe PPM as compared to those with no PPM (14.6% vs. 14.3% vs. 13.1%, respectively, log-rank p = 0.98). Neither moderate (OR = 1.6, 95% CI: 0.8-3.2, p = 0.16) nor severe PPM (OR = 1.67, 95% CI: 0.36-7.7, p = 0.51) had a significant impact on composite endpoint, or its elements, with the exception of transvalvular pressure gradient > 20 mm Hg. Conclusions Severe PPM after TAVI is rare, can be predicted by larger BSA and does not seem to affect mid-term mortality or composite clinical outcome. Larger studies are needed to find different independent predictors of PPM and elucidate its impact in terms of device durability and long-term clinical efficacy.
منابع مشابه
Transcatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملImpact of aortic annulus size on valve hemodynamics and clinical outcomes after transcatheter and surgical aortic valve replacement: insights from the PARTNER Trial.
BACKGROUND The objective was to evaluate the effects of aortic annulus size on valve hemodynamics and clinical outcomes in those patients included in the Placement of Aortic Transcatheter Valves (PARTNER) randomized controlled trial cohort A and the nonrandomized continued access cohort. METHODS AND RESULTS Patients included the randomized controlled trial (n=574) and nonrandomized continued ...
متن کاملClinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis
OBJECTIVE We sought to ascertain predictors of Patient Prosthesis Mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. METHOD We analyzed 2,107 sequential surgeries. Patient Prosthesis Mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. We defined nonsignificant, moderat...
متن کاملIncidence and management of CoreValve dislocation during transcatheter aortic valve implantation.
BACKGROUND Transcatheter aortic valve implantation is a highly specialized technique offering a new therapeutic option to patients at high risk for conventional surgery. Complications associated with this catheter procedure differ from complications after surgical aortic valve replacement. This is to report incidence, management, and impact on morbidity and mortality of CoreValve dislocation du...
متن کاملCirculation Topic Review
Transcatheter aortic valve implantation has been associated with a higher rate of cerebrovascular events (CVEs) compared with medical treatment or surgical aortic valve replacement. This multicenter study evaluated in a large cohort of consecutive patients (n=1061) the timing, predictors, and clinical impact of CVEs after transcatheter aortic valve implantation. The incidence of 30-day CVEs was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -
تاریخ انتشار 2017