Evaluation of Two Programs Developed for Dental Digital Subtraction Radiography: a Comparison between Different Methods of Geometric Alignment
نویسندگان
چکیده
Purpose: The aim of this research was to compare different methods of geometric alignment produced by two programs developed to be utilized for digital subtraction radiography (DSR). Material and Methods: Material consists of 50 pairs of intra-oral radiographs taken in 50 patients during normal oral clinical treatment. Two programs invented by the authors of this article: ToothVis 1.4 (TV) and DentalStudio 2.0 (DS) software were used in this study. Images obtained by two methods of DSR (cut and divide) and geometrically aligned with four methods were compared with the use of the peak signal to noise ratio (PSNR). Results: Analyzing the PSNR, it was observed that for cut subtraction its values ranged from 37.93 dB to 39.99 dB. For divide subtraction the PSNR values varied between 39.00 dB (03_pt_DS vs 10_pt_TV) and 47.73 dB (03_pt_TV vs 10_pt_TV). The PSNR achieved higher values for divide than for cut subtraction. Comparing cut and divide subtraction, the PSNR was the lowest for 3-point geometric alignment. Conclusion: Geometric alignment with the ToothVis software combined with divide subtraction gives the best quality of a subtracted image.
منابع مشابه
The Comparison between Two Different Digital Panoramic Radiography Techniques in the Detection of Proximal Caries
Introduction: Although proximal dental caries are very common, clinical examinations cannot detect them all. Panoramic radiography has been widely used in dentistry for both diagnosis and screening. This study aimed to investigate and compare the efficacy of two digital panoramic radiography techniques in the diagnosis of proximal caries. Methods: A total number of 60 patients referred to a den...
متن کاملEvaluation of Panoramic Radiography Accuracy in Estimating the Crestal Width of Dental Implant in Different Jaw Regions
Introduction: The aim of this study was to determine the accuracy of digital panoramic radiography in estimating the crestal width of implant fixtures after surgery. Materials and Methods:We selected 241 digital panoramic images after implant insertion which had documented information of their actual size. The crestal width was measured on radiographs. We compared two measuring methods in diff...
متن کاملComparison of the Diagnostic Accuracy of Digital Intraoral Radiography with PSP and CBCT in the Detection of Horizontal and Vertical Dental Root Fractures
Background and Aim: Clinical and radiographic diagnoses of dental root fractures have always been difficult and require high accuracy in dental care and treatment. The aim of this study was to compare the diagnostic accuracy of intraoral digital radiography (PSP) and CBCT in the detection of horizontal and vertical root fractures (HRF and VRF). Materials and Methods: For this experimental stud...
متن کاملIn vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection
Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of image quality and elimination of processing, it has been extensively used in different fields of dentistry in recent years. The purpose of this study wa...
متن کاملQuality comparison of direct digital panoramic radiography and computed radiography panoramic
BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...
متن کامل