Development of improved radiation therapy techniques using narrow scanned photon beams

نویسنده

  • Björn Andreassen
چکیده

The present thesis is focused on the development and application of narrow scanned high energy photon beams for radiation therapy. The introduction of physically and biologically optimized intensity modulated radiation therapy (IMRT) requires a flexible and accurate dose delivery method to maximize the treatment outcome. Narrow scanned photon beams is a fast option for IMRT since it is not dependent on mechanically moving heavy collimator leafs and is largely independent of the complexity of the desired dose distribution. Scanned photon beams can be produced by scanning an electron beam of low emittance, incident on a thin bremsstrahlung target of low atomic number. The large fraction of high energy electrons that are transmitted through the target has to be removed by a strong purging magnet. In the thesis a strong purging magnet, coupled with a magnetic scanning magnet, is presented for an intrinsic electron energy of 50 75 MeV and a source to isocenter distance of 75 cm. The available scan area at isocenter can be as large as 43 x 40 cm2 for an incident electron energy of 50 MeV and 28 x 40 cm2 at 75 MeV. By modifying the existing treatment head of the racetrack microtron MM50, it was possible to experimentally produce relevant dose distributions with interesting properties from 50 MV scanned narrow photon beams while deflecting the transmitted electrons onto a simplified electron stopper. The deflection of the transmitted electrons was studied both experimentally and by the Monte Carlo method. With high energy photons, treatment verification is possible through PETCT imaging of the positron annihilations induced by photonuclear reactions in the patient. Narrow scanned high energy photon beams is the ideal beam quality since the activation efficiency and the effective photon energy will be more uniform than the filtered photon beam from a full range bremsstrahlung target. The 11C activity induced by a 50 MV scanned narrow photon beam was measured using PET-CT imaging and compared with Monte Carlo simulations. The combination of fast flexible dose delivery with treatment verification using PET-CT imaging makes narrow high energy scanned photon beams a very interesting treatment modality for biologically optimized adaptive radiation therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of two radiation techniques in breast boost delivery

Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast can...

متن کامل

Fast IMRT with narrow high energy scanned photon beams.

PURPOSE Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, expe...

متن کامل

Quality Assurance of LINAC by Analyzing the Profile of 6-MV and 10-MV Photon Beams Using Star Track Device

Introduction: According to the American Society of Radiation Oncology, all patients receive radiation therapy during their illness, where radiation is delivered by the medical linear accelerator (Linac). The aim of this study was to evaluate the quality assurance (QA) of the Linac in analyzing the used dose profile in the treatment of cancer tumors. Materi...

متن کامل

Dosimetric comparison between XR-RV3 and EBT2 radiochromic film in megavoltage photon beams

Background:  Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...

متن کامل

Evaluation of Breast Cancer Radiation Therapy Techniques in Outfield Organs of Rando Phantom with Thermoluminescence Dosimeter

Background: Given the importance of scattered and low doses in secondary cancer caused by radiation treatment, the point dose of critical organs, which were not subjected to radiation treatment in breast cancer radiotherapy, was measured.Objective: The purpose of this study is to evaluate the peripheral dose in two techniques of breast cancer radiotherapy with two energies. Methods: Eight diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010