Degenerative changes of the interface membrane as a possible reason for prosthesis loosening.
نویسندگان
چکیده
OBJECTIVE The aim of the present study was to perform a comparative evaluation of septic and aseptic interface membranes, assessing histological features, inflammatory infiltrate, and expression of inflammatory cytokines. METHODS Septic and aseptic interface membranes from 102 patients were examined by histology, histochemistry, and immunohistochemistry (tissue arrays). The cell subpopulations were characterized by quantification of CD3, CD4, CD8, CD20, and CD163 positive cells. Additionally, a semiquantitative evaluation of inflammatory cytokines (TNFalpha, TGF-beta1, IL-1, IL-6, CRP, MMP-1, MMP-6) was performed to complete the analysis of inflammatory infiltrates. RESULTS The histological analysis revealed three different types of aseptic interface membranes: wear particle, degenerative, and mixed type. The expression of inflammatory molecules did not differ between septic and wear particle interface membranes. Significantly lower expression of cytokines, MMPs and CRP was observed, however, in degenerative interface membranes compared to other types. No expression of TNFalpha was observed in the degenerative interface membranes. Over 88% of patients with degenerative interface membranes had had a clinical record of osteoarthritis. CONCLUSION Aseptic interface membranes were represented by wear particle, degenerative and mixed type. The expression of inflammatory factors in wear particle type is similar to this in septic membranes and can contribute to the bone destruction and prosthesis loosening. These factors seem not to play a major role in the degenerative membranes.
منابع مشابه
Recurring synovitis as a possible reason for aseptic loosening of knee endoprostheses in patients with rheumatoid arthritis.
We evaluated histologically samples of synovial tissue from the knees of 50 patients with rheumatoid arthritis (RA). The samples were taken during revision for aseptic loosening. The findings were compared with those in 64 knees with osteoarthritis (OA) and aseptic loosening and in 18 knees with RA without loosening. The last group had been revised because of failure of the inlay or the couplin...
متن کاملCement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration
Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term im...
متن کاملEvaluating suppression of PGE2, PAF, and histamine synthesis and histopathological changes of bones in the membrane surrounding particulate polymethylmethacrylate in the rat tibia
Abstract Introduction: Inflammation and wear debris may be responsible for bone lysis and subsequent lost in aseptic arthroplasty. Prostaglandin E2, platelet activating factor, and histamine are important mediators of inflammatory cells. We studied histopathological changes of cement-bone interface after using specific antagonists of these mediators. Methods: Left and right tibiae...
متن کاملEvaluating the Frequency of Implant-Supported Fixed Prosthesis Complications in Yazd Dental School in 2020
Introduction: Evaluating the frequency of complications in implant supported prosthesis such as screw loosening and porcelain fracture is important for prevention and management of these problems. The purpose of this study was to evaluate the frequency of implant-supported fixed prosthesis complications in Yazd dental school in 2020. Methods: In this descriptive cross-sectional study, the pat...
متن کاملAn experimental animal model of aseptic loosening of hip prostheses in sheep to study early biochemical changes at the interface membrane
BACKGROUND Aseptic loosening of hip prosthesis as it occurs in clinical cases in human patients was attributed to wear particles of the implants, the response of the tissue dominated by macrophages and the production of inflammatory mediators and matrix degrading enzymes; however, the cascade of events initiating the process and their interaction regarding the time course is still open and disc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Histology and histopathology
دوره 23 8 شماره
صفحات -
تاریخ انتشار 2008