Advanced heart failure treated with continuous-flow left ventricular assist device.

نویسندگان

  • Mark S Slaughter
  • Joseph G Rogers
  • Carmelo A Milano
  • Stuart D Russell
  • John V Conte
  • David Feldman
  • Benjamin Sun
  • Antone J Tatooles
  • Reynolds M Delgado
  • James W Long
  • Thomas C Wozniak
  • Waqas Ghumman
  • David J Farrar
  • O Howard Frazier
چکیده

BACKGROUND Patients with advanced heart failure have improved survival rates and quality of life when treated with implanted pulsatile-flow left ventricular assist devices as compared with medical therapy. New continuous-flow devices are smaller and may be more durable than the pulsatile-flow devices. METHODS In this randomized trial, we enrolled patients with advanced heart failure who were ineligible for transplantation, in a 2:1 ratio, to undergo implantation of a continuous-flow device (134 patients) or the currently approved pulsatile-flow device (66 patients). The primary composite end point was, at 2 years, survival free from disabling stroke and reoperation to repair or replace the device. Secondary end points included survival, frequency of adverse events, the quality of life, and functional capacity. RESULTS Preoperative characteristics were similar in the two treatment groups, with a median age of 64 years (range, 26 to 81), a mean left ventricular ejection fraction of 17%, and nearly 80% of patients receiving intravenous inotropic agents. The primary composite end point was achieved in more patients with continuous-flow devices than with pulsatile-flow devices (62 of 134 [46%] vs. 7 of 66 [11%]; P<0.001; hazard ratio, 0.38; 95% confidence interval, 0.27 to 0.54; P<0.001), and patients with continuous-flow devices had superior actuarial survival rates at 2 years (58% vs. 24%, P=0.008). Adverse events and device replacements were less frequent in patients with the continuous-flow device. The quality of life and functional capacity improved significantly in both groups. CONCLUSIONS Treatment with a continuous-flow left ventricular assist device in patients with advanced heart failure significantly improved the probability of survival free from stroke and device failure at 2 years as compared with a pulsatile device. Both devices significantly improved the quality of life and functional capacity. (ClinicalTrials.gov number, NCT00121485.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Renal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device.

BACKGROUND The effects of continuous blood flow and reduced pulsatility on major organ function have not been studied in detail. METHODS AND RESULTS We evaluated renal (creatinine and blood urea nitrogen) and hepatic (aspartate transaminase, alanine transaminase, and total bilirubin) function in 309 (235 male, 74 female) advanced heart failure patients who had been supported with the HeartMat...

متن کامل

Apical pseudoaneurysm following continuous flow left ventricular assist device placement.

The HeartMate II continuous flow left ventricular assist device (LVAD) (Thoratec Inc) provides circulatory support for patients with medically refractory systolic heart failure as both a bridge to transplantation and destination therapy. Although left ventricular apical pseudoaneurysm has rarely been reported with first-generation pulsatile flow LVADs, this has not been previously reported with...

متن کامل

Successful thrombectomy for acute coronary thromboembolism during Heartmate II ventricular support.

Complications of hemostasis account for the most common adverse events during continuous-flow ventricular assist device support for advanced heart failure. Successful management of acute coronary thromboembolism during HeartMateII device support has not been described in the literature. We present a case of acute coronary thromboembolism of the left main trunk associated with angina and ventric...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The New England journal of medicine

دوره 361 23  شماره 

صفحات  -

تاریخ انتشار 2009