Access-Related Infections Involving the Buttonhole Technique.
نویسندگان
چکیده
PURPOSE In this study, we discuss a mechanism of development of access-related Staphylococcus aureus infections in patients on buttonhole (BH) method and logically construct a measure to prevent such infections on the basis of the mechanism. SUMMARY S. aureus can colonize a BH track. Once S. aureus colonizes a BH track, access-related infections may develop when the equilibrium is upset between the factors of host resistance and a level of bacterial growth in a BH track. Thus, the logically constructed measure to prevent access-related infections are as follows: (1) decolonization of S. aureus from a BH track by applying mupirocin ointment to a BH entry site when a patient has been proven to be a carrier of S. aureus in the track, (2) prevention of bacterial invasion of the BH track by a new method to remove a scab completely, and (3) control of bacterial growth in the BH track by disinfecting the site with diluted povidone-iodine solution (0.1% povidone-iodine solution) before access vessel cannulation.
منابع مشابه
Buttonhole versus rope-ladder cannulation of arteriovenous fistulas for hemodialysis: a systematic review.
BACKGROUND The buttonhole technique is an alternative method of cannulating the arteriovenous fistula (AVF) in hemodialysis (HD), frequently used for home HD patients. However, the balance of risks and benefits of the buttonhole compared with the rope-ladder technique is uncertain. STUDY DESIGN A systematic review of randomized trials and observational studies (case reports, case series, stud...
متن کاملFrequent Hemodialysis Fistula Infectious Complications
BACKGROUND Few studies have examined if infectious arteriovenous access complications vary with the cannulation technique and whether this is modified by dialysis frequency. We compared the infection rate between fistulas cannulated using buttonhole versus stepladder techniques for patients treated with short daily (SDH) or nocturnal hemodialysis at home (NHD). We also compared patients receivi...
متن کاملButtonhole cannulation and clinical outcomes in a home hemodialysis cohort and systematic review.
BACKGROUND AND OBJECTIVES The relative merits of buttonhole (or blunt needle) versus rope ladder (or sharp needle) cannulation for hemodialysis vascular access are unclear. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Clinical outcomes by cannulation method were reviewed in 90 consecutive home hemodialysis patients. Initially, patients were trained in rope ladder cannulation. From 2004 on, a...
متن کاملButtonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique.
BACKGROUND The rope-ladder puncture technique, with cannulation along the whole length of the vessel traject, has been very common in haemodialysis patients with autogenous arterio-venous fistula (AVF). Today's dialysis population with AVF may exhibit difficult cannulation, because of a short vein length or a complicated cannulation route. An alternative needling possibility is the buttonhole (...
متن کاملArterio-venous fistula buttonhole cannulation technique: a retrospective analysis of infectious complications
BACKGROUND There are two main methods of accessing arterio-venous fistulas (AVFs); the 'buttonhole' and the 'rope-ladder' cannulation technique. Several small studies have hypothesized that the buttonhole technique is associated with increased rates of fistula-associated infection. This study addresses this hypothesis. METHODS A retrospective review of all patients attending a large outpatien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Blood purification
دوره 41 4 شماره
صفحات -
تاریخ انتشار 2016