Posterior cervical spine arthrodesis with laminar screws: a report of two cases.
نویسندگان
چکیده
We performed fixation using laminar screws in 2 patients in whom lateral mass screws, pedicle screws or transarticular screws could not be inserted. One was a 56-year-old woman who had anterior atlantoaxial subluxation (AAS). When a guide wire was inserted using an imaging guide, the hole bled massively. We thought the re-insertion of a guide wire or screw would thus increase the risk of vascular injury, so we used laminar screws. The other case was an 18-year-old man who had a hangman fracture. Preoperative magnetic resonance angiography showed occlusion of the left vertebral artery. A laminar screw was inserted into the patent side (i.e., the right side of C2). Cervical pedicle screws are the most biomechanically stable screws. However, their use carries a high risk of neurovascular complications during screw insertion, because the cervical pedicle is small and is adjacent laterally to the vertebral artery, medially to the spinal cord, and vertically to the nerve roots. Lateral mass screws are also reported to involve a risk of neurovascular injuries. The laminar screw method was thus thought to be useful, since arterial injuries could thus be avoided and it could also be used as a salvage modality for the previous misinsertion.
منابع مشابه
Posterior occipito-axial fixation applied C2 laminar screws for pediatric atlantoaxial instability caused by Down syndrome: Report of 2 cases
BACKGROUND Upper cervical spine instability is one of the most critical orthopedic problems in patients with Down syndrome. However, arthrodesis of the upper cervical spine in these patients can be very difficult to achieve and has a high complication rate because of mental retardation and accompanying various medical conditions of the vital organs. Even now, surgeries in such patients, especia...
متن کاملLaminar screw fixation in the subaxial cervical spine: A report on three cases
Although laminar screw fixation is often used at the C2 and C7 levels, only few previous case reports have presented the use of laminar screws at the C3-C6 levels. Here, we report a novel fixation method involving the use of practical laminar screws in the subaxial spine. We used laminar screws in the subaxial cervical spine in two cases to prevent vertebral artery injury and in one case to min...
متن کاملDelayed Esophageal Pseudodiverticulum after Anterior Cervical Spine Fixation: Report of 2 Cases
Introduction: Although perforation of the esophagus, in the anterior cervical spine fixation, is well established, cases with delayed onset, especially cases that present pseudodiverticulum, are not common. In addition, management of the perforation in this situation is debated. Case Report: Delayed esophageal pseudodiverticulum was managed in two patients with a history of anterior spine fi...
متن کاملBiomechanical comparison of C1-C2 posterior arthrodesis techniques.
STUDY DESIGN Biomechanical comparison of 5 atlantoaxial posterior arthrodesis techniques. OBJECTIVE To assess the relative value of different posterior wire constructs when one or two transarticular screws are used. SUMMARY OF BACKGROUND DATA A combination of Gallie or Brooks techniques and 2 posterior transarticular screws has been shown to be effective for atlantoaxial arthrodesis. Anatom...
متن کاملBilateral Pedicle and Crossed Translaminar Screws in C2
Multiple techniques exist for the fixation of C2, including axial pedicle screws and bilateral translaminar screws. We describe a novel method of incorporating both the translaminar and pedicle screws within C2 to improve fixation to the subaxial spine in patients requiring posterior cervical instrumentation for deformity correction or instability. We report three cases of patients with cervica...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta medica Okayama
دوره 61 2 شماره
صفحات -
تاریخ انتشار 2007