Respiratory Motion Correction in Emission Tomography Imaging

نویسندگان

  • Mauricio Reyes
  • Grégoire Malandain
  • Pierre Malick Koulibaly
  • Jacques Darcourt
چکیده

During an emission tomography exam of lungs, respiratory motion blurs the reconstructed image, which may lead to misinterpretations and imprecise diagnosis. Solutions like respiratory gating, correlated dynamic PET techniques, listmode data based techniques and others have been tested with improvements over the spatial activity distribution in lungs lesions, but with the disadvantages of either requiring extra hardware or more expensive scanner systems, or discarding part of the acquired data. The objective of this study is to include a respiratory motion model in the image tomographic reconstruction process, which will allow to consider all the acquired data, without any additional requirement. To this end, we propose an extension of the MLEM reconstruction algorithm, in which we extend the probability matrix to take into account both the motion and the deformation of the voxels to be reconstructed. We present results from synthetic simulations incorporating real respiratory motion data, demonstrating the potential benefits of such an approach.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Respiratory Motion Correction in Emission Tomography Image Reconstruction

In Emission Tomography imaging, respiratory motion causes artifacts in lungs and cardiac reconstructed images, which lead to misinterpretations and imprecise diagnosis. Solutions like respiratory gating, correlated dynamic PET techniques, list-mode data based techniques and others have been tested with improvements over the spatial activity distribution in lungs lesions, but with the disadvanta...

متن کامل

List-Mode Affine Rebinning for Respiratory Motion Correction in PET Cardiac Imaging

Positron Emission Tomography (PET) is an established functional imaging modality but its practical deployment is hampered by motion artefacts. This paper proposes a method for correcting reconstructed PET images through a list-mode rebinning process. Respiratory motion is compensated for by applying 2D affine transforms to the respiratory gated sequence of line-ofresponse events prior to image ...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005