Correlation between Optic Nerve Parameters Obtained Using 3D Nonmydriatic Retinal Camera and Optical Coherence Tomography: Interobserver Agreement on the Disc Damage Likelihood Scale

نویسندگان

  • Jae Wook Han
  • Soon Young Cho
  • Kui Dong Kang
چکیده

Purpose. To compare stereometric parameters obtained by three-dimensional (3D) optic disc photography and optical coherence tomography (OCT) and assess interobserver agreement on the disc damage likelihood scale (DDLS). Methods. This retrospective study included 190 eyes from 190 patients classified as normal, glaucoma suspect, or glaucomatous. Residents at different levels of training completed the DDLS for each patient before and after attending a training module. 3D optic disc photography and OCT were performed on each eye, and correlations between the DDLS and various parameters obtained by each device were calculated. Results. We found moderate agreement (weighted kappa value, 0.59 ± 0.03) between DDLS scores obtained by 3D optic disc photography and the glaucoma specialist. The weighted kappa values for agreement and interobserver concordance increased among residents after the training module. Interobserver concordance was the poorest at DDLS stages 5 and 6. The DDLS scored by the glaucoma specialist had the highest predictability value (0.941). Conclusions. The DDLS obtained by 3D optic disc photography is a useful diagnostic tool for glaucoma. A supervised teaching program increased trainee interobserver agreement on the DDLS. DDLS stages 5 and 6 showed the poorest interobserver agreement, suggesting that caution is required when recording these stages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of nerve fiber layer thickness measurements using 3D fourier-domain OCT.

PURPOSE Conventional time-domain optical coherence tomography (OCT) has been shown to provide reproducible retinal nerve fiber layer (RNFL) measurements. Recently, high-speed, high-resolution Fourier-domain 3D-OCT has been introduced to improve OCT quality. It can provide 6-mm(2) high-density scans to provide RNFL thickness measurements. The purpose of this study was to test the reproducibility...

متن کامل

Correlation between Visual Field Index and Other Functional and Structural Measures in Glaucoma Patients and Suspects

PURPOSE To evaluate the correlation between visual field index (VFI) and both structural and functional measures of the optic disc in primary open angle glaucoma patients and suspects. METHODS In this retrospective study, 162 glaucoma patients and suspects underwent standard automated perimetry (SAP), retinography, and retinal nerve fiber layer (RNFL) measurement. The optic disc was stratifie...

متن کامل

Update on retinal vessel structure measurement with spectral-domain optical coherence tomography.

This study was conducted to demonstrate a new scan method for retinal vessel structure measurement in a specific region of fundus (zone B) using spectral-domain optical coherence tomography (SD-OCT), and to assess its reliability. One temporal superior retinal vessel pair passing through a concentric ring (zone B), which was defined between half and one disc distance from the optic disc border,...

متن کامل

Relationships between optic nerve damage and the severity of cognitive impairment in patients with mild cognitive impairment and Alzheimer’s disease

This study was to analyse the degeneration of the Retinal Nerve Fiber Layer (RNFL) and optic disc and the relationship between optic nerve damage and the severity of cognitive impairment in patients with Alzheimer’s disease (AD) and Mild Cognitive Impairment (MCI). The RNFL thickness and optic disc variables were assessed by optical coherence tomography in patients with MCI and AD and control s...

متن کامل

Software-Assisted Depth Analysis of Optic Nerve Stereoscopic Images in Telemedicine

Background. Software guided optic nerve assessment can assist in process automation and reduce interobserver disagreement. We tested depth analysis software (DAS) in assessing optic nerve cup-to-disc ratio (VCD) from stereoscopic optic nerve images (SONI) of normal eyes. Methods. In a prospective study, simultaneous SONI from normal subjects were collected during telemedicine screenings using a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014