Light beam diaphragm collimation errors and their effects on radiation dose for pelvic radiography.

نویسندگان

  • Hannah Brookfield
  • Anthony Manning-Stanley
  • Andrew England
چکیده

PURPOSE To investigate the range of collimation errors in x-ray rooms and to calculate their possible effects on the radiation dose for anteroposterior pelvic examinations. METHODS A collimator test tool was suspended at 3 heights (14, 21, and 28 cm) above the table Bucky in 9 x-ray rooms. Heights corresponded to the typical patient thickness (mean, ± 2 SD) of 67 patients undergoing anteroposterior pelvic radiography. The x-ray beam was visually collimated to the inner boundary of the test tool and exposed to radiation. Differences between the visualized field size and the resultant x-ray field size (corrected for magnification) indicated a collimation error. Next, using a pelvic phantom, minimum textbook collimation was set and then changed and verified to simulate a range of possible collimation errors. Phantom examinations used a standard anteroposterior technique with exposure termination using outer automatic exposure control chambers. Dose area product (DAP) was recorded. RESULTS All but 1 of the 9 x-ray machines had a smaller irradiated area than was visually set. Errors ranged from a 16% reduction in irradiated field size to a slight overirradiation by 0.4%. Assuming that these errors could be larger in other institutions, additional errors with a range of -27% to 18% were simulated. Increases in field size by 1 cm (superiorly/inferiorly) increased the DAP by 5%. Laterally, a 1-cm increase caused a 4% rise in DAP. Increases of 1 cm in both planes raised DAP by 4%. DISCUSSION Within a single clinical department, minimal collimation errors were demonstrated. Further evidence from multiple centers would be beneficial; however, such low incidences might reflect strict legislative requirements governing the use of ionizing radiation. Understanding the magnitude of any error is important, but it is also important to ascertain an error's influence on the effective radiation dose for any given examination. CONCLUSION Overall, collimation errors were minimal and favored underirradiation. Small collimation errors can affect DAP and are more dose significant in the superior/inferior plane.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam Collimation during Lumbar Spine Radiography: A Retrospective Study

Introduction: Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient’s radiation dose and to improve image quality during radiology practice. Lack or inadequate collimation results in excessive radiation dose to patients and deterioration image quality.Objective: To assess the quality of beam collimation dur...

متن کامل

Evaluation of the Entrance Surface Dose (ESD) and Radiation Dose to the Radiosensitive Organs in Pediatric Pelvic Radiography

Background Patients' dosimetry is crucial in order to enhance radiation protection optimization and to deliver low radiation dose to the patients in a radiological procedure. The aim of this study was to assess the entrance surface dose (ESD) and radiation dose to the radiosensitive organs in pediatric pelvic radiography. Materials and Methods The studied population included 98 pediatric patien...

متن کامل

Radioprotection to the Gonads in Pediatric Pelvic Radiography: Effectiveness of Developed Bismuth Shield

Background: The use and effectiveness of traditional lead gonad shields in pediatric pelvic radiography has been challenged by several literatures over the past two decades. The aim of this study was to develop a new radioprotective gonad shields to be use in pediatric pelvic radiography. Materials and Methods: The commercially available 0.06 mm lead equivalent bismuth garment has cropped squar...

متن کامل

Survey of the Use of X-ray Beam Collimator and Shielding Tools during Infant Chest Radiography

Background The use of shielding tools and X-ray beam collimator has extensively been advocated as effective methods to reduce radiation exposure to patients underwent radiological procedures. The aim of this study was to address the use of these protection measures during infant chest radiography. Material and Methods 348digital and/or analogue infant chest radiographs were reviewed that perfor...

متن کامل

Beam Collimation during Lumbar Spine Radiography: A Retrospective Study

INTRODUCTION Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient's radiation dose and to improve image quality during radiology practice. Lack or inadequate collimation results in excessive radiation dose to patients and deterioration image quality. OBJECTIVE To assess the quality of beam collimation duri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiologic technology

دوره 86 4  شماره 

صفحات  -

تاریخ انتشار 2015