Analytically exact correction scheme for signal extraction from noisy magnitude MR signals.
نویسندگان
چکیده
An analytically exact method is proposed to extract the signal intensity and the noise variance simultaneously from noisy magnitude MR signals. This method relies on a fixed point formula of signal-to-noise ratio (SNR) and a correction factor. The correction factor, which is a function of SNR, establishes a fundamental link between the variance of the magnitude MR signal and the variance of the underlying Gaussian noise in the two quadrature channels. A more general but very similar method is developed for parallel signal acquisitions with multiple receiver coils. In the context of MR imaging, the proposed method can be carried out on a pixel-by-pixel basis if the mean and the standard deviation of the magnitude signal are available.
منابع مشابه
روشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملBreaking the noise floor: A framework for correcting the noise-induced bias in noisy magnitude MR signals
Breaking the noise floor: A framework for correcting the noise-induced bias in noisy magnitude MR signals Cheng Guan Koay, Evren Özarslan, Peter J. Basser STBB / NICHD, National Institutes of Health, Bethesda, MD, United States MR signals are complex numbers where the real and imaginary components are independently Gaussian distributed [1]. The phase of the complex MRI signal is highly sensitiv...
متن کاملA framework for correcting the noise-induced bias in noisy magnitude MR signals
INTRODUCTION MR signals are complex numbers where the real and imaginary components are independently Gaussian distributed [1]. The phase of the complex MRI signal is highly sensitive to many experimental factors, e.g., see [1,2], and as such, the magnitude of the complex MR signal is used instead in quantitative studies. Although several techniques have been proposed to correct the phase error...
متن کاملCombination of Beamforming and Synchronization Methods for Epileptic Source Localization, using Simulated EEG Signals
Localization of sources in patients with focal seizure has recently attracted many attentions. In the severe cases of focal seizure, there is a possibility of doing neurosurgery operation to remove the defected tissue. The prosperity of this heavy operation completely depends on the accuracy of source localization. To increase this accuracy, this paper presents a new weighted beamforming method...
متن کاملRecognition of Multiple PQ Issues using Modified EMD and Neural Network Classifier
This paper presents a new framework based on modified EMD method for detection of single and multiple PQ issues. In modified EMD, DWT precedes traditional EMD process. This scheme makes EMD better by eliminating the mode mixing problem. This is a two step algorithm; in the first step, input PQ signal is decomposed in low and high frequency components using DWT. In the second stage, the low freq...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance
دوره 179 2 شماره
صفحات -
تاریخ انتشار 2006