Fault and Theft Recognition Using Toro Dial Sensor in Programmable Current Relay for Feeder Security
نویسندگان
چکیده
Feeder protection is important in transmission and distribution side because if any fault occurs in any feeder or transformer, man power is needed to identify the problem and it will take more time. In the existing system, directional overcurrent elements with load further secured by a load encroachment function can be used to provide necessary security and sensitivity for faults on remote points in a circuit. It is validated only in renewable plant collector circuit protection applications over a wide range of operating conditions. In this method, the directional overcurrent feeder protection is developed by using monitoring of feeder section through internet. In this web based monitoring, the fault and power theft are identified by using Toro dial sensor and its information is received by SCADA (Supervisory Control and Data Acquisition) and controlled by ARM microcontroller. This web based monitoring is also used to monitor the feeder management, directional current detection, demand side management, overload fault. This monitoring system is capable of monitoring the distribution feeder over a large area depending upon the cost. It is also used to reduce the power theft, time and man power. The simulation is done by MATLAB software. Keywords—Current sensor, distribution feeder protection, directional overcurrent, power theft, protective relay.
منابع مشابه
A New Restricted Earth Fault Relay Based on Artificial Intelligence
The restricted earth fault (REF) relay is a type of differential protection which is used for detection of internal ground faults of power transformers. But, during external faults and transformer energization conditions, the probability of current transformer (CT) saturation increases. Thus, the spurious differential current due to CT saturation, can lead to REF relay maloperation. In this pap...
متن کاملCurrent Directional Protection of Series Compensated Line Using Intelligent Classifier
Current inversion condition leads to incorrect operation of current based directional relay in power system with series compensated device. Application of the intelligent system for fault direction classification has been suggested in this paper. A new current directional protection scheme based on intelligent classifier is proposed for the series compensated line. The proposed classifier uses ...
متن کاملAnonymous Secure Relay Based Routing Protocol in Wireless Sensor Network
Present network communication protocol in wireless sensor network posses wide range of security vulnerabilities in routing data packets between the hops or base station (Server). It is impossible to detect such vulnerabilities and attackers exploit these vulnerabilities in order to penetrate into the network. Many researchers and security forum focus to overcome such vulnerabilities in routing ...
متن کاملارایه شاخصی جدید به منظور کاهش قیود در مساله هماهنگی بهینه رله های اضافه جریان با در نظر گرفتن عدم قطعیتها
In a realistic and large power system, the overcurrent relay coordination problem considering different network topologies and different location of faults is stated as an optimization problem with a large number of constraints. In this paper, a new index is proposed to detect and remove the inactive inequality constraints in relay coordination problem. This index is defined for each relay pair...
متن کاملDesigning of a New Transformer Ground Differential Relay Based on Probabilistic Neural Network
Low- impedance transformer ground differential relay is a part of power transformer protection system that is employed for detecting the internal earth faults. This is a fast and sensitive relay, but during some external faults and inrush current conditions, may be exposed to maloperation due to current transformer (CT) saturation. In this paper, a new intelligent transformer ground differentia...
متن کامل