Long-term CPAP Compliance in Women with Obstructive Sleep Apnoea

نویسندگان

  • Francisco Campos-Rodriguez
  • Miguel A. Martinez-Garcia
  • Isabel Caballero-Martinez
  • Carmen V. Almeida
  • Pablo Catalan-Serra
چکیده

Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea (OSA), but compliance and variables involved in longterm CPAP adherence in women with OSA are unknown. We performed an observational study including all consecutive women diagnosed with OSA who started CPAP treatment in two Spanish teaching hospitals between 1999 and 2007 and were followed-up until December 2010. The Kaplan-Meier method was used to calculate the probability to continue on CPAP treatment and a multivariate Cox regression analysis was used to identify baseline predictors of CPAP dropout. We analysed 708 women, median (IQR) age 60 (52-67) years and apnoeahypopnoea index 43.0 (27.2-66.8). Women were followed for a median of 6.2 (4.2-7.7) years. The probability of still being on CPAP at 5 and 10 years was 82.8% and 79.9%, respectively. The median CPAP use was 6 (IQR 4-7) hours/day. In the multivariate analysis, independent baseline predictors of CPAP dropout were psychoactive medication (HR 1.47, 95%CI 1.03-2.08), age (HR 1.01, 95%CI 1.00-1.03) and CPAP pressure (HR 0.89, 95% CI 0.81 to 0.96). Long-term CPAP adherence in women with OSA is good. Psychoactive medication and increasing age were independent predictors of CPAP dropout, whereas higher CPAP pressure was associated with continued treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term continuous positive airway pressure compliance in females with obstructive sleep apnoea.

Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea (OSA), but compliance and variables involved in long-term CPAP adherence in females with OSA are unknown. We performed an observational study including all consecutive females diagnosed with CPAP who started CPAP treatment in two Spanish teaching hospitals between 1999 and 2007 and were followed-u...

متن کامل

Insomnia symptoms and CPAP compliance in OSAS patients: A descriptive study using Data Mining methods.

BACKGROUND Obstructive Sleep Apnoea Syndrome (OSAS) and insomnia are common pathologies sharing a high comorbidity. CPAP is a cumbersome treatment. Yet, CPAP compliance must remain optimal in order to reverse excessive daytime sleepiness and prevent the cardiovascular consequences of OSAS. But chronic insomnia could negatively affect CPAP compliance. OBJECTIVE To assess the consequences of in...

متن کامل

Two months follow up of auto-CPAP treatment in patients with obstructive sleep apnoea.

BACKGROUND Continuous positive airway pressure (CPAP) with fixed mask pressure is the current standard treatment for obstructive sleep apnoea (OSA). Auto-CPAP devices apply at any time the minimally required pressure to normalise breathing and may improve patient comfort and compliance. We present an open descriptive study of auto-CPAP treatment at home in patients previously managed with conve...

متن کامل

A prospective observational study to evaluate the effect of social and personality factors on continuous positive airway pressure (CPAP) compliance in obstructive sleep apnoea syndrome

BACKGROUND Compliance with CPAP treatment for OSAS is not reliably predicted by the severity of symptoms or physiological variables. We examined a range of factors which could be measured before CPAP initiation to look for predictors of compliance. METHODS This was a prospective cohort-study of CPAP treatment for OSAS, recording; socio-economic status, education, type D personality and clinic...

متن کامل

Objective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome.

Compliance with nasal continuous positive airway pressure (CPAP) has become a major concern, since this treatment is efficacious, but constraining. In 46 consecutive obstructive sleep apnoea (OSA) patients, we measured compliance with nasal CPAP by establishing a mean rate of use, with a built-in time counter read at three-month intervals, over a mean follow-up period of 232 +/- 27 days. The me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013