Comparison of the clinical performance of PapilloCheck human papillomavirus detection with that of the GP5+/6+-PCR-enzyme immunoassay in population-based cervical screening.

نویسندگان

  • A T Hesselink
  • D A M Heideman
  • J Berkhof
  • F Topal
  • R P Pol
  • C J L M Meijer
  • P J F Snijders
چکیده

We compared the clinical performance of the PapilloCheck human papillomavirus (HPV) assay with that of the GP5+/6+-PCR method with an enzyme immunoassay readout (GP5+/6+-PCR-EIA) for the detection of high-risk HPV (hrHPV) types by the use of cervical samples originating from women in a population-based by the use of cervical screening cohort tested by combined cytology and GP5+/6+-PCR-EIA (POBASCAM trial). Specimens from a random sample of 1,437 controls (women ages 40 to 60 years with normal cytological findings and without evidence of cervical intraepithelial neoplasia grade 2 or higher [> or = CIN2] within up to 8 years of follow-up) and 192 cases (women ages 30 to 60 years in whom > or = CIN3 was detected within up to 3 years of follow-up) were subjected to analysis by the PapilloCheck method. When all 17 (probably) hrHPV types were taken into account, the PapilloCheck assay had a clinical sensitivity for the detection of > or = CIN3 of 96.4% (185/192 samples; 95% confidence interval [CI], 93.7 to 99.7) and a clinical specificity for the detection of > or = CIN2 of 96.3% (95% CI, 95.3 to 97.3). After restriction of the analysis by the PapilloCheck assay to the 14 hr HPV types targeted by GP5+/6+-PCR-EIA, the clinical sensitivity and clinical specificity values were 95.8% (95% CI, 92.8 to 98.8) and 96.7% (95% CI, 95.7 to 97.7), respectively. By comparison, these values were 96.4% (95% CI, 93.9 to 98.9) and 97.7% (95% CI, 96.9 to 98.5), respectively, for the GP5+/6+-PCR-EIA. When all 17 (probably) hrHPV types were included in the analysis, noninferiority score testing revealed that the clinical sensitivity of the PapilloCheck assay for the detection of > or = CIN3 was noninferior to that of the GP5+/6+-PCR-EIA (P < 0.0001), but the clinical specificity of the PapilloCheck assay for the detection of > or = CIN2 was inferior to that of the GP5+/6+-PCR-EIA (P = 0.08) when lower bounds of 90% for sensitivity and 98% for specificity were used. When the analysis was restricted to the 14 hrHPV types targeted by the GP5+/6+-PCR-EIA, both the clinical sensitivity and the clinical specificity of the PapilloCheck assay were noninferior to those of the GP5+/6+-PCR-EIA (noninferiority score test; P < 0.0001 and P = 0.007, respectively). Thus, when the findings obtained for the 14 hrHPV types detectable by the GP5+/6+-PCR-EIA are considered, the PapilloCheck assay is clinically compatible with the GP5+/6+-PCR-EIA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

GP5+/6+ PCR followed by reverse line blot analysis enables rapid and high-throughput identification of human papillomavirus genotypes.

In this study, we developed a simple and fast typing procedure for 37 mucosotropic human papillomavirus (HPV) types using a nonradioactive reverse line blotting (RLB) procedure for general primer (GP5+/6+) PCR products. This system has the advantages not only that in a simple format, up to 42 PCR products can be simultaneously typed per membrane per day, but also that after stripping, the membr...

متن کامل

Cross-sectional comparison of an automated hybrid capture 2 assay and the consensus GP5+/6+ PCR method in a population-based cervical screening program.

In this cross-sectional study, clinical performances of the hybrid capture 2 assay using an automated instrument (i.e., rapid capture system) (hc2-RCS) and the high-risk human papillomavirus GP5+/6+ PCR-enzyme immunoassay (EIA) test were compared using cervical scrape specimens from 8,132 women that participated in a population-based screening trial. The hc2-RCS test scored significantly more s...

متن کامل

Clinical and Analytical Performance of the Onclarity HPV Assay Using the VALGENT Framework.

As the demand for human papillomavirus (HPV)-related cervical screening increases, emerging HPV tests must be evaluated robustly using well-annotated samples, such as those generated in the Validation of HPV Genotyping Tests (VALGENT) framework. Through VALGENT, we assessed the performance of the BD Onclarity HPV assay, which detects 14 high-risk (HR) types and resolves six individual types and...

متن کامل

Correction for Geraets et al., Clinical Evaluation of a GP5+/6+-Based Luminex Assay Having Full High-Risk Human Papillomavirus Genotyping Capability and an Internal Control.

The LMNX genotyping kit HPV GP (LMNX) is based on the clinically validated GP5+/6+ PCR, with a genotyping readout as an alternative for the more established enzyme immunoassay (EIA) detection of 14 targeted high-risk human papillomavirus (HPV) types. LMNX is additionally provided with an internal control probe. Here, we present an analysis of the clinical performance of the LMNX using a sample ...

متن کامل

Comparison of three different PCR methods for quantifying human papillomavirus type 16 DNA in cervical scrape specimens.

We compared real-time LightCycler and TaqMan assays and the GP5+/6+ PCR/enzyme immunoassay (EIA) to assess the human papillomavirus type 16 (HPV16) load in cervical scrape specimens. Both real-time PCR assays determined the HPV16 load in scrape specimens similarly. The level of agreement between these assays and the GP5+/6+ PCR/EIA was low (P = 0.004), suggesting that the latter method is not s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 2010