Comparison of Laryngoscopic View and Hemodynamic Changes with Flexitip McCoy and Macintosh Laryngoscope Blade in Predicted Easy and Difficult Airway
نویسندگان
چکیده
Objective: To compare the laryngoscopic view and the hemodynamic changes by using flexitip McCoy laryngoscope with Macintosh laryngoscope. Method: Study design-Prospective randomized controlled study. A total of 220 patients were included in the study, Patients were allocated on the basis of their airway anatomy in to two groups, one is predicted easy group and the other one was predicted difficult airway group. Among each group, half of the patient intubation was performed with Macintosh blade and the other half was intubated with the help of McCoy blade. The airway prediction was done on the basis of Mallampati grade, thyromental distance, inter incisor gap, jaw protrusion and weight of the patient. Larygoscopic view and hemodynamic changes were recorded. Results: The change in pulse rate was significantly (p = 0.01) higher among the patients of Group B (85.02 ± 10.13) as compared to Group A (79.20 ± 13.11) after induction in predicted easy patients. Similar observation was found for pulse rate after laryngoscopy among both predicted easy and difficult patients. The diastolic blood pressure was significantly (p = 0.0001) higher in Group B (86.34 ± 9.78) than Group A (77.12 ± 11.66) after induction among predicted easy patients. However, diastolic blood pressure was significantly (p = 0.0004) higher in Group A (82.00 ± 10.98) compared with Group B (75.00 ± 9.06) after induction among predicted difficult patients. The average time taken during laryngoscopy was insignificantly (p > 0.05) higher in Group B (13.90 ± 5.95) compared with Group A (12.42 ± 3.58) among predicted easy patients. However, the time taken was significantly (p = 0.0001) higher in Group A (20.83 ± 2.47) than Group B (12.66 ± 3.0) in predicted difficult patients. A majority of the patients of both the groups were in Grade I (Group A = 61.8%, Group B = 81.8%) followed by Grade II (Group A = 38.2%, Group B = 18.2%) among predicted easy patients. Conclusion: It was concluded that the McCoy blade may be an answer to Macintosh blade in difficult airway cases, but not the substitute of Macintosh blade in every cases. The McCoy blade improved laryngeal view in patients with limited neck extension.
منابع مشابه
Comparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملThe effects of callander modification of laryngoscopic blade on hemodynamic changes according to the degree of difficult airway
Background: Laryngoscopy and tracheal intubation are known to have profound cardiovascular effects. The Callander modification of Macintosh blade is associated with greater field of laryngoscopic view and decreased risk of dental contact. The purpose of this study was to compare the hemodynamic responses to laryngoscopy and tracheal intubation according to the degree of difficult airway, and to...
متن کاملComparison of McGrath® Series 5 video laryngoscope with Macintosh laryngoscope: A prospective, randomised trial in patients with normal airways
OBJECTIVE The McGrath Video laryngoscope is a newly developed video laryngoscope that significantly improves laryngeal view and facilitates endotracheal intubation in difficult airways. However in patients with normal airway that is not mentioned before. The aim of this study was to compare the McGrath video laryngoscope with the Macintosh laryngoscope in patients with normal airways. METHODS...
متن کاملComparison of the C-MAC D-Blade, Conventional C-MAC, and Macintosh Laryngoscopes in Simulated Easy and Difficult Airways.
OBJECTIVE Recently, to further enhance the potential in the management of difficult airways, the highly angulated D-Blade was added to the C-MAC system. The purpose of this study was to investigate the laryngoscopic view and intubation parameters using the new C-MAC D-Blade in comparison to the conventional C-MAC video laryngoscope and Macintosh direct laryngoscope in simulated easy and difficu...
متن کاملDesign evaluation of commonly used rigid and levering laryngoscope blades.
BACKGROUND The shape of a laryngoscope blade affects the exposition of the larynx. This study evaluates and compares some rigid and levering blade designs based on previous investigative X-ray laryngoscopic studies. METHODS Five rigid laryngoscope blades (Miller #3, Standard Macintosh #3, Classical Macintosh #4 and English-Macintosh #3 and #4) and two levering laryngoscope blades (McCoy in ne...
متن کامل