Optimization of Ga-67 imaging for detection and estimation tasks: dependence of imaging performance on spectral acquisition parameters.
نویسندگان
چکیده
UNLABELLED We have compared the use of two (93 and 185 keV) and three (93, 185, and 300 keV) photopeaks for Ga-67 tumor imaging and optimized the placement of each energy window. METHODS The bases for optimization and evaluation were ideal and Bayesian signal-to-noise ratios (SNR) for the detection of spheres embedded in a realistic anthropomorphic digital torso phantom and ideal SNR for the estimation of their size and activity concentration. Seven spheres of radii ranging from 1 to 3 cm, located at several sites in the torso, were simulated using a realistic Monte Carlo program. We also calculated the ideal SNR for the detection from simple phantom acquisitions. RESULTS For detection and estimation tasks, the optimum windows were identical for all sphere sizes and locations. For the 93 keV photopeak, the optimal window was 84-102 keV for the detection and 87-102 keV for estimation; these windows are narrower than the 20% window often used in the clinic (83-101 keV). For the 185 keV photopeak, the optimal window was 170-220 keV for the detection and 170-215 keV for estimation; these are substantially different than the 15% window used in our clinic (171-199 keV). For the 300 keV photopeak, the optimal window for detection was 270-320 keV, and for estimation, 280-320 keV. Using the three optimized, rather than only the two lower-energy, windows yielded a 9% increase in the SNR for the detection of the 3 cm diam sphere (a 12% increase for a 2 cm diam sphere) and a 7% increase in the SNR for estimation of its size. For the acquired phantom data, detection also increased by 9%-12% when using three, rather than two, energy windows.
منابع مشابه
Development of Ga-67 Maltolate Complex as an Imaging Agent
Due to the antitumor activity of Gallium MAL complex, as well as recent findings on new targeted biomolecules in malignant cells through this complex, the development of radiolabeled gallium complex for future imaging studies was targeted. Ga-67 labeled 3-hydroxy-2-methyl-4H-pyran-4-onate (Ga-67 MAL) was prepared using freshly prepared Ga-67 chloride and 3-hydroxy-2-methyl-4H-pyran-4-onate in a...
متن کاملDevelopment of Ga-67 Maltolate Complex as an Imaging Agent
Due to the antitumor activity of Gallium MAL complex, as well as recent findings on new targeted biomolecules in malignant cells through this complex, the development of radiolabeled gallium complex for future imaging studies was targeted. Ga-67 labeled 3-hydroxy-2-methyl-4H-pyran-4-onate (Ga-67 MAL) was prepared using freshly prepared Ga-67 chloride and 3-hydroxy-2-methyl-4H-pyran-4-onate in a...
متن کامل A novel approach to automatic position calibration for pixelated crystals in gamma imaging
Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we pr...
متن کاملتعیین ماشینهای بردار پشتیبان بهینه در طبقهبندی تصاویر فرا طیفی بر مبنای الگوریتم ژنتیک
Hyper spectral remote sensing imagery, due to its rich source of spectral information provides an efficient tool for ground classifications in complex geographical areas with similar classes. Referring to robustness of Support Vector Machines (SVMs) in high dimensional space, they are efficient tool for classification of hyper spectral imagery. However, there are two optimization issues which s...
متن کاملOptimization of Bremsstrahlung imaging in Yttrium internal radiation therapy
Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 29 8 شماره
صفحات -
تاریخ انتشار 2002