Effect of Blood Exposure on Push-Out Bond Strength of Four Calcium Silicate Based Cements

نویسندگان

  • Kazem Ashofteh Yazdi
  • Behnam Bolhari
  • Tohid Sabetmoghaddam
  • Naghmeh Meraji
  • Mohammad Javad Kharazifard
چکیده

INTRODUCTION The purpose of this study was to compare the push-out bond strength of white ProRoot Mineral Trioxide Aggregate (MTA), Biodentine, calcium-enriched mixture (CEM) cement and Endosequence Root Repair Material (ERRM) putty after exposure to blood. METHODS AND MATERIALS A total of 96 root dentin slices with a standardized thickness of 1.00±0.05 mm and standardized canal spaces were randomly divided into 4 main experimental groups (n=24) according to the calcium silicate based cement (CSC) used: white ProRoot MTA, CEM Cement, ERRM Putty and Biodentine. Specimens were exposed to whole fresh human blood and then subdivided into two subgroups depending on the exposure time (24 or 72 h). Push-out bond strength was measured using a universal testing machine. Failure modes were examined under a light microscope under ×10 magnification. Data were analyzed using the two-way ANOVA test. RESULTS Biodentine exhibited the highest values regardless of the exposure time. The lowest push-out strength values were seen in white ProRoot MTA and CEM cement in both post exposure times. After exposure to blood, the push-out bond strength of all materials increased over time. This increase was only statistically significant in white ProRoot MTA and ERRM specimens. The dominant failure mode in all CSCs was the adhesive mode. CONCLUSION Biodentine showed the highest values of push-out bond strength and may be better options for situations encountering higher dislocation forces in a short time after cement application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Impact of Thermocycling Process on the Dislodgement Force of Different Endodontic Cements

To evaluate the effects of thermocycling (500 cycles, 5°C/55°C) on the push-out bond strength of calcium silicate based cements including WMTA, Nano-WMTA, and Bioaggregate to root dentin. Forty-eight dentin slices were prepared and divided into 3 groups (n = 16) and filled with Angelus WMTA, Nano-WMTA, or Bioaggregate. After incubation, half of the samples were thermocycled while the other half...

متن کامل

Apical adaptation, sealing ability and push-out bond strength of five root-end filling materials.

This study compared the fluid filtration, adaptation to the root canal walls, and the push-out bond strength of two resin-based sealers and three calcium silicate-based retrograde filling materials. Fifty maxillary canines were shaped using manual instruments and the apical portion was sectioned. Retrograde cavities of 3-mm depth were prepared. The specimens were divided into five groups (n = 1...

متن کامل

The effect of smear layer on the push-out bond strength of root canal calcium silicate cements.

INTRODUCTION The aim of this study was to evaluate the effect of smear layer removal on the push-out bond strength between radicular dentin and three calcium silicate cements (CSC) in comparison with gutta percha and sealer. METHODS Eighty human anterior extracted teeth were decoronated, cleaned and shaped to size 50/0.05 apically and randomly divided into 2 major groups: (A) smear layer pres...

متن کامل

The Effect of BC Sealer, AH-Plus and Dorifill on Push-out Bond Strength of Fiber Post

Introduction Dentinal canal walls are in direct contact with endodontic sealers prior to post space preparation and luting cements after post space preparation. This direct contact may affect the bond strength of intraradicular posts to root dentin. This study aimed to assess the effect of three different sealers on the bond strength of fiber posts to root dentin. Methods and Materials The ca...

متن کامل

Push-out bond strength of MTA HP, a new high-plasticity calcium silicate-based cement.

This study was designed to investigate the resistance to dislodgment provided by MTA HP, a new high-plasticity calcium silicate-based cement. Biodentine and White MTA Angelus were used as reference materials for comparison. Three discs 1 ± 0.1 mm thick were obtained from the middle third of the roots of 5 maxillary canines. Three 0.8-mm-wide holes were drilled on the axial surface of each root ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017