Fetal Adrenal Gland in the Second Half of Gestation: Morphometrical Assessment with 3.0T Post-Mortem MRI

نویسندگان

  • Zhonghe Zhang
  • Haiwei Meng
  • Zhongyu Hou
  • Jun Ma
  • Lei Feng
  • Xiangtao Lin
  • Yuchun Tang
  • Xiaoli Zhang
  • Qingwei Liu
  • Shuwei Liu
چکیده

BACKGROUND The morphometry of fetal adrenal gland is rarely described with MRI of high magnetic field. The purpose of this study is to assess the normal fetal adrenal gland length (AL), width (AW), height (AH), surface area (AS) and volume (AV) in the second half of gestation with 3.0T post-mortem MRI. METHODS AND FINDINGS Fifty-two fetal specimens of 23-40 weeks gestational age (GA) were scanned by 3.0T MRI. Morphological changes and quantitative measurements of the fetal adrenal gland were analyzed. Asymmetry and sexual dimorphism were also obtained. The shape of the fetal adrenal gland did not change substantially from 23 to 40 weeks GA. The bilateral adrenal glands appeared as a 'Y', pyramidal or half-moon shape after reconstruction. There was a highly linear correlation between AL, AW, AH, AS, AV and GA. AW, AH, AS and AV were larger for the left adrenal gland than the right. No sexual dimorphism was found. CONCLUSIONS Our data delineated the normal fetal adrenal gland during the second half of gestation, and can serve as a useful precise reference for anatomy or in vivo fetus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adrenal insufficiency due to hemorrhage in a premature neonate:A case report

Neonatal adrenal hemorrhage is more common than previously suspected.in most cases the diagnosis is made by post-mortem autopsy.however massive hemorrhage is less common.the most important cause is  trauma during birth,other contributing factors are:macrosomia,diabetic mothers,breech presentation,congenital syphilis,anoxia,hemorrhagic disease, and prematurity.clinical manifestations of the dise...

متن کامل

Fetal blood flow measured using phase contrast MRI-comparison of image quality and flow volume at 1.5T with 3.0T

Background Ultrasound is commonly used for the antenatal assessment of a fetus and it can provide functional and haemodynamic data in addition to anatomical details. The accuracy of the former is dependant on angle of insonation, maternal habitus and fetal position. Phase contrast cardiovascular magnetic resonance (PC CMR) has emerged as a clinical tool for blood flow quantification but its use...

متن کامل

Morphometrical Evaluation of Corpus Callosum Using Mid-Sagittal Brain MRI Images in Patients With Relapsing-Remitting Multiple Sclerosis Referred to Besat Hospital in Hamadan from April 2011 To April 2021; A Retrospective Study

Introduction: Corpus callosum (CC) as an intracranial organ is located in midline of cerebrum communicating both right and left hemispheres. CC undergoes morphological changes in multiple sclerosis (MS). Since the morphometrical changes of organs are directly associated with geographical regions, thus the aim of this study was to investigate the morphological alteration of CC in patients with r...

متن کامل

Morphometrical Assessment of Suprarenal Gland in Fetuses of Different Gestational Age Groups

The study was made on morphometric parameters of human fetal suprarenal gland. The present study was carried out in the department of Anatomy, Government Medical College & Hospital, Chandigarh. The material for the study consisted of 30 spontaneously aborted human fetal specimens from 12th to 28th weeks of gestational ages. The suprarenal glands and kidney were taken from fetal specimens for mo...

متن کامل

Effects of Noise Exposure on the Volume of Adrenal Gland and Serum Levels of Cortisol in Rat

Background: Noise pollution is considered as a stressful factor in every day’s life of the industrial world. The present study was designed to investigate the probable effects of different time exposure of noise stress on histomorphometric changes of adrenal gland, plasma cortisol and body weight of the rat. Methods: Sixty adult male Wistar rats were divided into two series of short time noise ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013