Aortic obstruction caused by device occlusion of patent arterial duct.
نویسندگان
چکیده
A 2 year old girl is reported in whom deployment of the Amplatzer ductal occluder caused significant aortic obstruction, requiring surgical removal of the device. This case emphasises the need for careful echocardiographic and angiographic assessment of the position of the Amplatzer ductal occluder before and after detaching the device from its delivery system, with particular emphasis on the position of the aortic retention ring. Careful assessment of ductal anatomy must guide case selection.
منابع مشابه
Chronic hypobaric hypoxia, patent arterial duct and a new interventional technique to close it.
BACKGROUND Interventional closure of patent arterial duct has become an accepted alternative to surgical closure. Clinical trial with "Nit-Occlud® PDA-R". METHODS AND RESULTS To assess the safety and efficacy of the device, we performed a prospective clinical study between June, 2009 and December, 2010 in La Paz, Bolivia. In all, 29 - 22 female patients and 7 male patients - out of 59 patient...
متن کاملAcquired aortic regurgitation following occlusion of the persistent arterial duct: an echocardiographic assessment.
OBJECTIVE To document the development of aortic regurgitation following occlusion of a patent arterial duct. DESIGN Case series involving nine children referred for surgical ligation of an isolated patent arterial duct. SETTING Academic referral centre. METHODS A preoperative transthoracic and transoesophageal echocardiogram was performed in theatre to look for aortic regurgitation. There...
متن کاملStenting of the arterial duct: a new approach to palliation for pulmonary atresia.
OBJECTIVE To assess the possibility of maintaining ductal patency in neonates with complex pulmonary atresia by percutaneous implantation of balloon expandable stents. PATIENTS Two duct-dependent neonates with long segment pulmonary atresia, right sided aortic arch, and left sided arterial duct. RESULTS Stents with final diameter of 3.5 or 4 mm and initial length of 7 or 15 mm were successf...
متن کاملEarly implantation of multiple spring coils for severe haemolysis after incomplete transcatheter occlusion of persistent arterial duct.
An 18 month old girl with an angiographically measured ductus of 4.5 mm underwent transcatheter occlusion of the persistent arterial duct with a 17 mm Rashkind umbrella and an occluding spring coil. Severe intravascular haemolysis developed 20 hours later. Significant residual ductal leakage was noted and the residual duct measured 6 mm. Previous underestimation might have been related to ducta...
متن کاملAcute coronary syndrome and platypnoea-orthodeoxia with thoracic and interauricular septal aneurysms.
OBJECTIVE Platypnea-orthodeoxia is a rare syndrome characterized by dyspnea induced by the upright position and relieved by supine position and an arterial deoxygenation increased by the upright position which improves during recumbency. Several anatomical factors that can alter the atrial anatomy and facilitate shunting through an interatrial defect have been related to this syndrome. In many ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 82 1 شماره
صفحات -
تاریخ انتشار 1999