Effect of low-xenon and krypton supplementation on signal/noise of regional CT-based ventilation measurements.
نویسندگان
چکیده
Xenon computed tomography (Xe-CT) is used to estimate regional ventilation by measuring regional attenuation changes over multiple breaths while rebreathing a constant Xe concentration ([Xe]). Xe-CT has potential human applications, although anesthetic properties limit [Xe] to <or=35%. We investigate effects of lower [Xe], including a low [Xe]-krypton (Kr) combination, on time constant (TC) determination. Six anesthetized sheep were scanned prone and supine using multidetector row CT. Lungs were imaged by respiratory gating during washin of a 30%, 40%, 55% Xe, and a 30% Xe/30% Kr mixture. Using Kr avoids unwanted effects of Xe. Mean TCs, coefficients of variation (CV), and half confidence intervals (CI)/mean served as indexes of sensitivity to noise. Mean supine and prone TCs of three [Xe] values were not significantly different. Average CVs of TCs increased from 57% (55% Xe), 58% (40% Xe), and 73% (30% Xe) (P < 0.05: paired t-tests; 30% Xe vs. higher [Xe]). Monte Carlo simulation indicated a CV based on inherent image noise was 8% for 55% Xe and 17% for 30% Xe (P < 0.05). Adding 30% Kr to 30% Xe gave a washin signal equivalent to 40% Xe. Half CI/mean using the 30% Xe/30% Kr mixture was not significantly different from 55 and 40% Xe. Although average TCs were not affected by changes in [Xe], the higher CV and half CI/mean suggested reduced signal-to-noise ratio at the 30% [Xe]. The 30% Xe/30% Kr mixture was comparable to that of 40% Xe, providing an important agent for CT-based assessment of regional ventilation in humans.
منابع مشابه
Continuing Education Ventilation Scintigraphy
Ventilation scintigraphy is a well-established adjunct to perfusion lung imaging in the diagnosis of pulmonary thromboembolus (PE). Although PE may be diagnosed with a standard chest radiograph and perfusion scintigraphy, the findings may be largely nonspecific due to the many types oflung pathology that result in perfusion defects. The specificity of the perfusion (Q) study may be substantiall...
متن کاملShearlet-Based Adaptive Noise Reduction in CT Images
The noise in reconstructed slices of X-ray Computed Tomography (CT) is of unknown distribution, non-stationary, oriented and difficult to distinguish from main structural information. This requires the development of special post-processing methods based on the local statistical evaluation of the noise component. This paper presents an adaptive method of reducing noise in CT images employing th...
متن کاملThe in vivo autoradiographic measurement of regional cerebral blood flow using stable xenon and computerized tomography: the effect of tissue heterogeneity and computerized tomography noise.
We have studied the effect of brain tissue (gray matter-white matter) heterogeneity and computerized tomography (CT) noise on the accuracy of xenon CT measurements of regional cerebral blood flow (rCBF) based upon "autoradiographic" and multiple-scan washin protocols. The results of our mathematical analysis indicate that both protocols are associated with a variety of measurement errors that l...
متن کاملA Novel Noise Reduction Method Based on Subspace Division
This article presents a new subspace-based technique for reducing the noise of signals in time-series. In the proposed approach, the signal is initially represented as a data matrix. Then using Singular Value Decomposition (SVD), noisy data matrix is divided into signal subspace and noise subspace. In this subspace division, each derivative of the singular values with respect to rank order is u...
متن کامل2 1 Fe b 20 03 Gas gain and signal length measurements with a triple - GEM at different pressures of Ar - , Kr - and Xe - based gas mixtures ⋆
We investigate the gas gain behaviour and the energy resolution of a triple-GEM configuration in gas mixtures of argon, krypton and xenon with ten and thirty percent of carbon dioxide at pressures between 1 and 3 bar. Since the signal widths affect the dead time behaviour of the detector we present signal length measurements to evaluate the use of the triple-GEM in time-resolved X-ray imaging.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 102 4 شماره
صفحات -
تاریخ انتشار 2007