Pair of resonant fiducial markers for localization of endovascular catheters at all catheter orientations.
نویسندگان
چکیده
PURPOSE To test wireless resonance circuits (RC) to be used as fiducial marker of endovascular catheters during MR-guided interventions. Current markers loose their signal enhancement for certain catheter orientations. The purpose of this study was to test a marker setup which overcomes this orientation problem. MATERIALS AND METHODS The markers were constructed from a pair of two RCs. The RCs were individually tuned and the coil axes were oriented perpendicular to each other in order to decouple the two RCs. The markers were mounted on the tip of endovascular catheters and tested in vitro and in one porcine in vivo experiment. RESULTS An intense MR signal at similar signal levels was noted at all catheter orientations. In the in vivo experiment the markers allowed for fast and reliable MR guidance of the catheters. CONCLUSION A pair of two individually tuned and decoupled RCs is well suited for MR guidance of endovascular catheters.
منابع مشابه
بررسی ارتباط زمان ماندگاری کاتترهای وریدی محیطی در نوزادان و کودکان بستری با میزان بروز عوارض رگگیری
Background & Aim: Peripherally intravenous catheters (PIVs) are an important part of therapy for hospitalized children. Although such catheters provide necessary vascular access, their use puts patients at risk for local and systemic infectious complications with serious morbidity. Migration of skin organisms at the insertion site into the coetaneous catheter tract with colonization of the cath...
متن کاملAntibacterial Modification of Intravascular Catheter Surface for the Prevention of Catheter-Associated Infection
Objective: Intravascular catheter-associated infection has been increasing hospitalization in post-surgery patients mainly due to microbial colonization of the catheter surface and formation of a superficial biofilm layer. The present study is aimed in developing an effective antibacterial device which can prevent colonization of organisms by modification of catheter. Methods: In the present st...
متن کاملAntibacterial Modification of Intravascular Catheter Surface for the Prevention of Catheter-Associated Infection
Objective: Intravascular catheter-associated infection has been increasing hospitalization in post-surgery patients mainly due to microbial colonization of the catheter surface and formation of a superficial biofilm layer. The present study is aimed in developing an effective antibacterial device which can prevent colonization of organisms by modification of catheter. Methods: In the present st...
متن کاملA Comparative Study on Using Coiled Versus Straight Swan-Neck Tenckhoff Catheters in Patients Undergoing Peritoneal Dialysis
The key to successful long-term peritoneal dialysis (PD) is permanent and safe access to peritoneal cavity. The two most commonly used Tenckoff catheters for PD are the straight and coiled catheters. The present study was undertaken to assess the catheter survival, catheter associated infections, and all cause mortality and to compare the straight with coiled catheters in PD. During April 1997-...
متن کاملعوارض و ماندگاری کاتترگذاری دیالیز صفاقی بهروش لاپاراسکوپی در بیماران تحت دیالیز صفاقی مداوم
Background: Laparoscopic techniques for the placement of peritoneal dialysis catheters are becoming increasingly popular. Recently, with the improvements in laparoscopic surgery, various methods for the insertion of peritoneal dialysis catheters have been reported, indicating that the laparoscopic insertion is preferred over the open and percutaneous techniques. The aim of this study was to int...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 17 5 شماره
صفحات -
تاریخ انتشار 2003