Raise the bar and lower the dose: current and future strategies for radiation dose reduction in head and neck imaging.
نویسندگان
چکیده
SUMMARY Technologic advances in CT have generated a dramatic increase in the number of CT studies, with a resultant increase in the radiation dose related to CT scanning. Such increase in radiation dose is becoming a concern for the radiology community, especially with increasing public awareness of the dose burden related to examinations. To cope with the increase in CT-related radiation exposure, it is becoming necessary to optimize CT imaging protocols and apply radiation dose reduction techniques to ensure the best imaging with the lowest radiation dose.
منابع مشابه
Thyroid dose and dose reduction method from CT scan of head and neck
Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...
متن کاملRadiation Induced Demyelination in Cervical Spinal Cord of the Head and Neck Cancer Patients after Receiving Radiotherapy
Background: Cervical spinal cord is important and radiosensitive. It is the most critical organ for the head and neck (H&N;) cancer patients during radiotherapy. If the delivered dose to the cord is more than tolerance dose, demyelination may occur. Objective: Current study aims to analyze the post radiotherapy status of cord in the H&N; cancer patients.Material and Methods: In this a...
متن کاملA prospective radiobiological study of acute esophagitis and swallowing dysfunction in head-and-neck radiotherapy
Introduction: Esophagitis is one of the main causes of swallowing dysfunction after radiation therapy (RT) for head and neck cancer (HNC).It significantly affects patients’ quality of life as well as having a potentially negative impact on their long term survival. However, little has been investigated on the dose-response and normal tissue complication probability (NTCP) of es...
متن کاملUtilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy
Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...
متن کاملAssessment of Radiation Dose to the Lens of the Eye and Thyroid of Patients Undergoing Head and Neck Computed Tomography at Five Hospitals in Mashhad, Iran
Introduction: In recent years, the number of computed tomography (CT) scans, which is a high-dose technique, has increased significantly. Head and neck CT is performed frequently and thyroid, particularly in children, has always been considered a sensitive organ. In recent years, radiobiologists and health physicists have been more concerned about the safety of lenses of the eyes, as cataract i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 35 4 شماره
صفحات -
تاریخ انتشار 2014