Fluid Uptake by Patients During Cardiopulmonary Bypass: An Oxygenator Dependent Phenomenon

نویسندگان

  • J. D. Brooks
  • R. A. Magrath
  • R. A. Beauchamp
  • R. E. Clark
چکیده

A significant difference in the amount of crystalloid solution necessary to maintain the patient with adequate perfusion was first noted between two bubble oxygenators being used clinically for the past two years at the Barnes Hospital, St. Louis, Missouri. This clinical study was established to determine the degree of difference of positive fluid balance to the patient as a result of cardiopulmonary bypass. The objective of this study was to test the hypothesis that positive fluid balance to the patient following cardiopulmonary bypass is a function of the type of oxygenator used, provided all other variables remain equal in standard, routine practice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo uptake and elimination of isoflurane by different membrane oxygenators during cardiopulmonary bypass.

BACKGROUND Volatile anesthetics are frequently used during cardiopulmonary bypass (CPB) to maintain anesthesia. Uptake and elimination of the volatile agent are dependent on the composition of the oxygenator. This study was designed to evaluate whether the in vivo uptake and elimination of isoflurane differs between microporous membrane oxygenators containing a conventional polypropylene (PPL) ...

متن کامل

Changes in sevoflurane plasma concentration with delivery through the oxygenator during on-pump cardiac surgery.

BACKGROUND It is unclear what factors affect the uptake of sevoflurane administered through the membrane oxygenator during cardiopulmonary bypass (CPB) and whether this can be monitored via the oxygenator exhaust gas. METHODS Stable delivery of sevoflurane was administered to 30 elective cardiac surgery patients at 1.8 vol% (inspiratory) via the anaesthetic circuit and ventilator. During CPB,...

متن کامل

Extraction of Nitroglycerin by a Membrane Oxygenator

This study examined the extraction efficiency of a membrane oxygenator for nitroglycerin (NTG). An In-Vitro cardiopulmonary bypass circuit was constructed to mimic clinical conditions. A NTG solution (150 ng/ml) was placed into the circuit via a glass cardiotomy reservoir and circulated at 5 Ll min for 60 min. Analysis of NTG samples obtained during the study showed that the oxygenator initiall...

متن کامل

Hypoxaemia during cardiopulmonary bypass.

For cardiopulmonary bypass during open-heart surgery we use a bubble oxygenator and a technique of haemodilution and moderate hypothermia. During the course of routine perfusion we have observed arterial desaturation in a number of patients and in five patients the desaturation was marked (SaO2<85%)'. The low arterial oxygen saturations occurred mainly in the rewarming period. This report is of...

متن کامل

The effects of cardiopulmonary bypass with hollow fiber membrane oxygenator on blood clotting measured by thromboelastography.

In cardiac surgical patients we investigated the effects of cardiopulmonary bypass (CPB) with a hollow fiber membrane oxygenator on blood clotting measured by thromboelastography (TEG). We found only a minimal change in the strength of blood clot described either by the TEG parameter MA (maximum amplitude) or by the shear modulus G calculated from MA. After CPB there was also a significant tend...