Geometrical consequences of kissing stents and the Covered Endovascular Reconstruction of the Aortic Bifurcation configuration in an in vitro model for endovascular reconstruction of aortic bifurcation.
نویسندگان
چکیده
OBJECTIVE Kissing stents (KS) are commonly used to treat aortoiliac occlusive disease, but patency results are often lower than those of isolated stents. The Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) technique was recently introduced to reconstruct the aortic bifurcation in a more anatomical and physiological fashion. The aim of this study is to compare the geometrical consequences of various stent configurations in vitro. METHODS Anatomic vessel phantoms of the aortoiliac bifurcation were created to accommodate stent configurations. Self-expandable nitinol KS, balloon-expandable covered KS, and two versions of the CERAB configuration were deployed, one with the iliac legs positioned inside the tapered part of the aortic cuff (1) and one with the legs deployed above this level (2). Computed tomography data were obtained to assess the geometry. The conformation ratio (D-ratio) was calculated by use of the ratio of the major and minor axes. The proximal mismatch area, mean mismatch area, and total mismatch volume were calculated. RESULTS The highest D-ratios were observed in the nitinol KS and the CERAB configuration, implying an ideal "double-D" shape. The proximal and mean mismatch areas were four- to sixfold lower in the CERAB (1) configuration when compared with nitinol KS and CERAB (2), respectively, whereas the covered KS had the highest mismatch area. Nitinol and covered KS had the largest mismatch volume, whereas the mismatch volume was the lowest in the CERAB (1) configuration. CONCLUSIONS Although nitinol self-expandable stents have a high stent conformation, the lowest radial mismatch was found in the CERAB (1) configuration, supporting the hypothesis that the CERAB configuration is the most anatomical and physiological reconstruction of the aortic bifurcation. Within the CERAB configuration, the two limbs are ideally positioned inside the tapering portion of the cuff, minimizing mismatch.
منابع مشابه
In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease
Objectives Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcati...
متن کاملCovered endovascular reconstruction of aortic bifurcation (CERAB) technique: a new approach in treating extensive aortoiliac occlusive disease.
Endovascular treatment of occlusive disease of the aortic bifurcation is challenging. We developed the Covered Endovascular Reconstruction of Aortic Bifurcation or CERAB-technique, as a new approach for extensive and/or recurrent aortoiliac occlusive disease using three covered balloon expandable stents to reconstruct the aortic bifurcation. This configuration provides the ability to deal with ...
متن کاملInfluence of Iliac Stenotic Lesions on Blood Flow Patterns Near a Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) Stent Configuration
PURPOSE To investigate the effect of distal stenotic lesions on flow patterns near a covered endovascular reconstruction of the aortic bifurcation (CERAB) configuration used in the treatment of aortoiliac occlusive disease. METHOD Laser particle image velocimetry measurements were performed using in vitro models of the aortic bifurcation with and without a CERAB configuration in place. A hemo...
متن کاملStent-supported reconstruction of the aortoiliac bifurcation with the kissing balloon technique.
BACKGROUND Bilateral iliac artery obstructions involving the aortic bifurcation or high-grade stenosis of the abdominal aorta are not usually considered an indication for percutaneous treatment. The purpose of the present study was to evaluate the initial and long-term results of primary stent implantation for reconstruction of the aortic bifurcation. METHODS AND RESULTS In 48 patients with o...
متن کاملAn Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess
Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vascular surgery
دوره 61 5 شماره
صفحات -
تاریخ انتشار 2015