The use of cyclic voltammetry to detect biofilms formed by Pseudomonas fluorescens on platinum electrodes.
نویسندگان
چکیده
The development of an electrochemical detector to monitor the in situ formation of biofilms is described. The detector consisted of an electrochemical cell containing three electrodes, whose response to the application of a potential profile to the working electrode was sensitive to the amount of biofilm present on the surface. The electrochemical technique used was repetitive cyclic voltammetry. Differences between the response of the uncolonised electrode and after Pseudomonas fluorescens biofilms of different ages were grown on its surface were determined. The results show that cyclic voltammetry applied to platinum electrodes can be used to detect young biofilms. The development of the shape of the voltammogram as the potential is cycled may constitute a means of providing information on the coverage of the surface. Observation of the platinum electrodes before and after the electrochemical measurements showed that even after 30 min of recycling, most of the cells were still adhered to the surface, although some may have lost viability.
منابع مشابه
Wst 47.5 B1.8
The effect of experimental conditions on cyclic voltammetry experiments on platinum electrodes covered with biofilms formed by Pseudomonas fluorescens for 2 hours was investigated. Results show that recycling the potential stabilizes the shape of the cyclic voltammogram after 135 cycles, but the observation of the electrodes by epifluorescence microscopy showed that cells are still adhered to t...
متن کاملMonitoring biofilm formation by using cyclic voltammetry-effect of the experimental conditions on biofilm removal and activity.
The effect of experimental conditions on cyclic voltammetry experiments on platinum electrodes covered with biofilms formed by Pseudomonas fluorescens for 2 hours was investigated. Results show that recycling the potential stabilizes the shape of the cyclic voltammogram after 195 cycles, but the observation of the electrodes by epifluorescence microscopy showed that cells are still adhered to t...
متن کاملPlatinum Nanoparticle Electrode Modified Iodine using Cyclic Voltammetry and Chronoamperometry for Determination of Ascorbic Acid
This study investigated the oxidation of ascorbic acid (Vitamin C) using a platinum nanoparticle electrode coated with an iodine monolayer, called a modified electrode. The electrode were grown using the cyclic voltammetry technique and the electrochemical measurements were taken using the cyclic voltammetry and chronoamperometric technique. In the case of platinum nanoparticle electrode modifi...
متن کاملCyclic voltammetry of bulk and nano manganese sulfate with Doxorubicin using glassy Carbon electrode
The cyclic voltammetry of both bulk manganese sulfate (BMS) and nano manganese sulfate (NMS) were studied using 0.1M KCl supporting electrolyte and glassy carbon working electrode. The redox behavior for both bulk (BMS) and MnSO4 (NMS) sulfate was studied voltammetrically in presence and absence of Doxorubicin (DR) using three electrodes system, silver- silver chloride (Ag/AgCl), pla...
متن کاملCyclic voltammetry of bulk and nano manganese sulfate with Doxorubicin using glassy Carbon electrode
The cyclic voltammetry of both bulk manganese sulfate (BMS) and nano manganese sulfate (NMS) were studied using 0.1M KCl supporting electrolyte and glassy carbon working electrode. The redox behavior for both bulk (BMS) and MnSO4 (NMS) sulfate was studied voltammetrically in presence and absence of Doxorubicin (DR) using three electrodes system, silver- silver chloride (Ag/AgCl), pla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biofouling
دوره 19 4 شماره
صفحات -
تاریخ انتشار 2003