Dark-Adapted Chromatic Perimetry for Measuring Rod Visual Fields in Patients with Retinitis Pigmentosa

نویسندگان

  • Lea D. Bennett
  • Martin Klein
  • Kirsten G. Locke
  • Kelly Kiser
  • David G. Birch
چکیده

PURPOSE Although rod photoreceptors are initially affected in retinitis pigmentosa (RP), the full-field of rod vision is not routinely characterized due to the unavailability of commercial devices detecting rod sensitivity. The purpose of this study was to quantify rod-mediated vision in the peripheral field from patients with RP using a new commercially available perimeter. METHODS Participants had one eye dilated and dark-adapted for 45 minutes. A dark-adapted chromatic (DAC) perimeter tested 80 loci 144° horizontally and 72° vertically with cyan stimuli. The number of rod-mediated loci (RML) were analyzed based on normal cone sensitivity (method 1) and associated with full-field electroretinography (ERG) responses by Pearson's r correlation and linear regression. In a second cohort of patients with RP, RML were identified by two-color perimetry (cyan and red; method 2). The two methods for ascribing rod function were compared by Bland-Altman analysis. RESULTS Method 1 RML were correlated with responses to the 0.01 cd.s/m2 flash (P < 0.001), while total sensitivity to the cyan stimulus showed correlation with responses to the 3.0 cd.s/m2 flash (P < 0.0001). Method 2 detected a mean of 10 additional RML compared to method 1. CONCLUSIONS Scotopic fields measured with the DAC detected rod sensitivity across the full visual field, even in some patients who had nondetectable rod ERGs. Two-color perimetry is warranted when sensitivity to the cyan stimulus is reduced to ≤20 dB to get a true estimation of rod function. TRANSLATIONAL RELEVANCE Many genetic forms of retinitis pigmentosa (RP) are caused by mutations in rod-specific genes. However, treatment trials for patients with RP have relied primarily on photopic (cone-mediated) tests as outcome measures because there are a limited number of available testing methods designed to evaluate rod function. Thus, efficient methods for quantifying rod-mediated vision are needed for the rapidly increasing numbers of clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal function abnormalities in patients treated with vigabatrin.

OBJECTIVE To evaluate central and peripheral retinal function in patients treated with vigabatrin, an antiepileptic drug associated with peripheral visual field constriction (VFC). METHODS Six patients with epilepsy treated with vigabatrin as add-on therapy for at least 3 years were included in this observational case series. All patients underwent a clinical ophthalmologic examination, color...

متن کامل

Blue Cone Monochromacy: Visual Function and Efficacy Outcome Measures for Clinical Trials

BACKGROUND Blue Cone Monochromacy (BCM) is an X-linked retinopathy caused by mutations in the OPN1LW / OPN1MW gene cluster, encoding long (L)- and middle (M)-wavelength sensitive cone opsins. Recent evidence shows sufficient structural integrity of cone photoreceptors in BCM to warrant consideration of a gene therapy approach to the disease. In the present study, the vision in BCM is examined, ...

متن کامل

Autosomal dominant retinitis pigmentosa in a large family: a clinical and molecular genetic study.

PURPOSE To characterize the pedigree, visual function phenotype, and responsible mutation in a large family with autosomal dominant retinitis pigmentosa. METHODS Pedigree data were obtained by personal interviews and corroborated with community records. One hundred twenty-eight members of the family were examined clinically, and a subset of 12 affected subjects was further studied with dark- ...

متن کامل

The relationship between rod perimetric thresholds and full-field rod ERGs in retinitis pigmentosa.

Dark-adapted static perimetric fields and rod full-field electroretinograms (ERGs) were measured in normal subjects and 15 patients with retinitis pigmentosa. Psychophysical thresholds for short-wavelength stimuli were obtained from 76 locations across the retina on a modified Octopus 201 perimeter; threshold differences to short- and long-wavelength stimuli were used to determine whether rods ...

متن کامل

Reliability and consistency of dark-adapted psychophysical measures in advanced eye disease.

PURPOSE To establish reliable vision measures allowing functional monitoring in patients with severe vision loss. METHODS Legally blind and normally sighted subjects were enrolled in a repeated-measures study to determine the reproducibility of psychophysical vision measures under scotopic conditions. The tests included dark adaptometry, dark-adapted, full-field flash testing, and dark-adapte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017