Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window.
نویسندگان
چکیده
Two methods of measuring stroke volume and cardiac output with pulsed Doppler two-dimensional echocardiography were developed and validated against the thermodilution technique in 39 patients, 33 of which were in an intensive care unit. With the use of the apical four-chamber view, a mitral inflow method combined the velocity of left ventricular inflow at the mitral anulus with the cross-sectional area of the anulus calculated from its diameter at middiastole (area = pi r2). From the apical five-chamber view a left ventricular outflow method combined the velocity of left ventricular outflow with the cross-sectional area of the aortic anulus calculated from its diameter during early systole (parasternal long-axis view). Measurements with the mitral inflow and left ventricular outflow methods were obtained in 35 of 39 (90%) and 39 of 39 (100%) patients, respectively. Validation of the mitral method excluded patients with mitral regurgitation (n = 11) and validation of the left ventricular outflow method excluded those with aortic regurgitation (n = 4). Good correlations were observed between thermodilution and Doppler measurements of stroke volume and cardiac output for both the mitral anulus method (R = .96 and .87, respectively) and the left ventricular outflow method (R = .95 and .91, respectively). The results of the two methods correlated well with each other in patients without regurgitant valve lesions. A greater interobserver variability was observed with the mitral anulus method, which was related solely to greater variability in measuring the annular diameter.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Normal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran
The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...
متن کاملNormal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran
Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...
متن کاملDoppler echocardiographic determination of stroke volume and cardiac output : clinical validation of two new methods using the apical window
Two methods of measuring stroke volume and cardiac output with pulsed Doppler twodimensional echocardiography were developed and validated against the thermodilution technique in 39 patients, 33 of which were in an intensive care unit. With the use of the apical four-chamber view, a mitral inflow method combined the velocity of left ventricular inflow at the mitral anulus with the crosssectiona...
متن کاملCorrelation between esCCO and transthoracic echocardiography in critically ill patients.
1 Bataille B, Bertuit M, Mora M, et al. Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care. Br J Anaesth 2012; 109: 879–86 2 Thom O, Taylor DM, Wolfe RE, et al. Comparison of a supra-sternal cardiac output monitor (USCOM) with the pulmonary artery catheter. Br J Anaesth 2009; 103: 800–4 3 Ishihara H, Okawa H, Tanabe K, et al. A n...
متن کاملPulsed Doppler echocardiographic determination of stroke volume and cardiac output
Two methods of measuring stroke volume and cardiac output with pulsed Doppler twodimensional echocardiography were developed and validated against the thermodilution technique in 39 patients, 33 of which were in an intensive care unit. With the use of the apical four-chamber view, a mitral inflow method combined the velocity of left ventricular inflow at the mitral anulus with the crosssectiona...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 70 3 شماره
صفحات -
تاریخ انتشار 1984