Optimal timing of same-admission orthotopic heart transplantation after left ventricular assist device implantation
نویسندگان
چکیده
AIM To investigate the impact of timing of same-admission orthotopic heart transplant (OHT) after left ventricular assist device (LVAD) implantation on in-hospital mortality and post-transplant length of stay. METHODS Using data from the Nationwide Inpatient Sample from 1998 to 2011, we identified patients 18 years of age or older who underwent implantation of a LVAD and for whom the procedure date was available. We calculated in-hospital mortality for those patients who underwent OHT during the same admission as a function of time from LVAD to OHT, adjusting for age, sex, race, household income, and number of comorbid diagnoses. Finally, we analyzed the effect of time to OHT after LVAD implantation on the length of hospital stay post-transplant. RESULTS Two thousand and two hundred patients underwent implantation of a LVAD in this cohort. One hundred and sixty-four (7.5%) patients also underwent OHT during the same admission, which occurred on average 32 d (IQR 7.75-66 d) after LVAD implantation. Of patients who underwent OHT, patients who underwent transplantation within 7 d of LVAD implantation ("early") experienced increased in-hospital mortality (26.8% vs 12.2%, P = 0.0483) compared to patients who underwent transplant after 8 d ("late"). There was no statistically significant difference in age, sex, race, household income, or number of comorbid diagnoses between the early and late groups. Post-transplant length of stay after LVAD implantation was also not significantly different between patients who underwent early vs late OHT. CONCLUSION In this cohort of patients who received LVADs, the rate of in-hospital mortality after OHT was lower for patients who underwent late OHT (at least 8 d after LVAD implantation) compared to patients who underwent early OHT. Delayed timing of OHT after LVAD implantation did not correlate with longer hospital stays post-transplant.
منابع مشابه
Orthotopic heart transplant versus left ventricular assist device: a national comparison of cost and survival.
OBJECTIVES Orthotopic heart transplantation is the standard of care for end-stage heart disease. Left ventricular assist device implantation offers an alternative treatment approach. Left ventricular assist device practice has changed dramatically since the 2008 Food and Drug Administration approval of the HeartMate II (Thoratec, Pleasanton, Calif), but at what societal cost? The present study ...
متن کاملTreatment of chronic ascites due to right-sided heart failure by transjugular intrahepatic portosystemic shunt stent-implantation after orthotopic heart transplant.
Long-term outcome after orthotopic heart transplant is often critical in patients with long-persisting right-sided heart failure and consecutive ascites. Transjugular intrahepatic portosystemic stent shunt is an effective treatment for chronic ascites. However, a case of transjugular intrahepatic portosystemic stent shunt implantation after orthotopic heart transplant and left ventricular assis...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملLimited mechanical circulatory support following orthotopic heart transplantation.
Shortage of donors enhances harvesting of borderline hearts. When such organs fail, a ventricular assist device may salvage the patient waiting for either recovery or for retransplantation. We describe a series of 12 patients who required circulatory support following orthotopic heart transplantation, with the use of four different devices. Four patients survived. The aim of this study is to de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2017