Comparison of optic nerve head parameter measurements obtained by time-domain and spectral-domain optical coherence tomography.

نویسندگان

  • Giacomo Savini
  • Piero Barboni
  • Michele Carbonelli
  • Alessandra Sbreglia
  • Giulia Deluigi
  • Vincenzo Parisi
چکیده

PURPOSE To compare the measurements of the optic nerve head (ONH) parameters provided by time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT). METHODS Four ONH parameters were analyzed: optic disc area, rim area, cup-to-disc area ratio (CDR), and vertical cup-to-disc ratio (VCDR). Stratus OCT and Cirrus HD-OCT were used to obtain measurements by TD-OCT and SD-OCT, respectively. Stratus OCT measurements were collected before and after manual correction of the ONH edges. RESULTS Twenty healthy participants and 20 patients with glaucomatous eyes were enrolled. Although manual correction of Stratus OCT measurements reduced the differences compared with Cirrus HD-OCT, the latter measured a smaller mean disc area than Stratus OCT in healthy (2.02±0.31 vs. 2.18±0.29 mm2, P=0.0003) and glaucomatous eyes (1.92±0.35 vs. 2.19±0.38 mm2, P<0.0001). Cirrus HD-OCT measured a smaller rim area than Stratus OCT in healthy (1.31±0.30 vs. 1.56±0.32 mm2, P<0.0001) and glaucomatous eyes (0.80±0.25 vs. 0.97±0.36 mm2, P=0.0052), a higher CDR (0.55±0.11 vs. 0.49±0.11, P<0.0001) and VCDR in healthy eyes (0.55±0.11 vs. 0.49±0.11, P<0.0001), and a higher CDR in glaucomatous eyes (0.74±0.10 vs. 0.58±0.18, P<0.0001). No statistically significant differences were detected for VCDR in glaucomatous eyes. All measured values showed good correlation (r≥0.70). Large 95% limits of agreement between the 2 devices were found for most parameters. CONCLUSIONS ONH parameter measurements provided by TD-OCT and SD-OCT show significant differences and cannot be considered interchangeable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

Polarization-sensitive spectral-domain optical coherence tomography using a single line scan camera.

Polarization-sensitive optical coherence tomography can be used to measure the birefringence of biological tissue such as the human retina. Previous measurements with a time-domain polarization-sensitive optical coherence tomography system revealed that the birefringence of the human retinal nerve fiber layer is not constant, but varies as a function of location around the optic nerve head. Her...

متن کامل

Predictors of normal optic nerve head, retinal nerve fiber layer, and macular parameters measured by spectral domain optical coherence tomography.

PURPOSE To evaluate the effects of signal strength, age, sex, optic disc size, and axial length on the normal optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular measurements with spectral domain optical coherence tomography (SD-OCT). METHODS In an observational, cross-sectional study, 119 eyes of 60 normal subjects of Indian origin underwent ONH, RNFL, and macular imaging w...

متن کامل

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

A Phase-sensitive Optical Coherence Tomography (OCT) Based Optical Electrode for Non-contact Neural Recording

A non-contact optical method for minimally invasive neural recording is designed and implemented. This method is based on phase-resolved spectral domain optical coherence tomography (SD-OCT). The optical electrode system is calibrated by performing phase measurements from a glass slide and some preliminary experiments of optical imaging and phase measurements in optic nerve of Limulus polyphemu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of glaucoma

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 2013