Patient and pacemaker survival after pacemaker implantation.

نویسندگان

  • P D Levin
  • R W Sessions
  • M Passovoy
  • R A Carleton
چکیده

One hundred thirty patients have had 244 pacemakers of five types implanted at Presbyterian-St. Luke’s Hospital in the past eight years. There has been I 0.50 probabilIty of successful unit function at only 12 months with epicardial units. All transvenous units used have had a 0.50 probabilIty of unit success at more than 17 months. This fact, combined with the lower frequency of early death with fransvenous units, has led to our opinion that epicardial units no longer have a place unless a thoracotomy is mandatory for other reasons.The data of the present study suggestan augmented early mortality with fixed rate transvenous units compared with a unit which synchronizes with the intrinsic ventricular rhythm. This, with the comparable unit reliability, will lead us to use ventricular synchronous *rans,enous units increasingly in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

Pacemaker Twiddler's Syndrome

A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...

متن کامل

Complete Congenital Heart Block in a Neonatal Lupus Erythematosus Associated with Pulmonary Involvement without Pacemaker Implantation: A Case Report

Background: Neonatal lupus erythematosus is an uncommon disease. Congenital complete heart block (CCHB) usually happens in neonates with maternal systemic lupus erythematosus. The most prevalent presentation of CCHBis bradycardiathatcanbediagnosed through an electrocardiogram. Case report: Here in, we present the case of a full-term male neonate with gestational age of 37 weeks and birth weigh...

متن کامل

The Effect of a Self-Care Program on the Quality of Life of Patients with Permanent Pacemaker

Introduction. Today, the subject of patient education as well as education for their families is mainly about acceptance of self-care by patients. Therefore, proper conditions should be provided for patients to be able to take care of themselves. This study attempts to examine the effects of a self-care program on quality of life of patients having permanent pacemaker. Methods. A quasi-experim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 1970