Sympathetic swelling response of the control eye to soft lenses in the other eye.

نویسندگان

  • D Fonn
  • R du Toit
  • T L Simpson
  • J A Vega
  • P Situ
  • R L Chalmers
چکیده

PURPOSE To compare central corneal swelling and light scatter after 8 hours of sleep in eyes wearing high- and low-Dk hydrogel lenses and to the contralateral control eyes. METHODS Twenty neophyte subjects wore a Lotrafilcon A (Dk, 140; Ciba Vision, Duluth GA) silicone hydrogel lens and an Etafilcon A (Dk, 18; Acuvue; Vistakon, Jacksonville, FL) 58% water content hydrogel lens of similar center thickness in random order in the right eye only, for overnight 8-hour periods. The contralateral nonwearing left eyes served as controls. Central corneal thickness was measured using an optical pachometer and light scatter using a Van den Berg stray-light meter before lens insertion, after lens removal on waking, and every 20 minutes for the next 3 hours. RESULTS Central corneal swelling induced by the Etafilcon A lens on eye opening was significantly higher than with the Lotrafilcon A lens (8.66%+/-2.84% versus 2.71%+/-1.91%; P<0.00001). Light scatter induced by the Etafilcon A lens on eye opening was significantly higher than with the Lotrafilcon A lens (46.09+/-5.62 versus 42.78+/-6.07 Van den Berg units, P = 0.0078). The swelling of the control eyes paired with the Etafilcon A lens-wearing eyes was also slightly but significantly higher than that of the control eyes paired with the Lotrafilcon A lens-wearing eyes (2.34%+/-1.26% versus 1.44%+/-0.91%; P = 0.0002). Light-scatter measurements were not significantly different between control sets of eyes but showed the same trend. CONCLUSIONS In neophyte subjects, corneal swelling of the contralateral control eyes appears to be influenced by the swelling of the fellow lens-wearing eyes-that is, the swelling of the contralateral control eye was significantly lower when there was less swelling of the fellow eye wearing the high-Dk lens. Although there was no statistically significant difference in light-scatter measurements between the control sets of eyes, a trend similar to the corneal swelling results was observed, which could be used to support the suggestion that this may be a sympathetic physiological response rather than an unusual sampling coincidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Head CT Protocol to Reduce the Absorbed Dose in Eye Lenses and Thyroid: A Phantom Study

Introduction: Utilization of computed tomography (CT) scans is increasing annually. This study aimed to reduce the absorbed dose of sensitive organs in the head (eye lenses and thyroid) and to assess changes in resultant images quality in head scans when the radiation dose is decreased. Material and Methods: An anthropomorphic phantom was examined with head protocols in both helical and sectio...

متن کامل

گزارش سه مورد کراتیت آکانتامبایی در یزد

Acanthamoeba keratitis is a vision- threatening infection and the most important risk factors are contact lenses Characteristic symptoms include disproportionately severe ocular pain, epithelial ulcer, ring stromal infiltrate and resistance to antimicrobial treatment. The aim is to report the first cases of Acanthamoeba keratitis in Yazd in a retrospective study confirmed on histopathological ...

متن کامل

Effect of Soft Knee Support on Dynamic and Static Balance in the Male Elderly

Objectives: Joint supporters can caused increasing proprioceptive information. Such proprioceptive information is needed for balance. The purpose of this study was to determine the effect of soft knee support on static and dynamic balance tests in male elderly (65 years and older). Methods & Materials: Via a randomized clinical trial study design, 22 elderly were selected and divided into tw...

متن کامل

Evaluation of Occupational Radiation Status and Validity of Individual Dose and Eye Lens Assessment Using Single Film Dosimeter for Angiographic Staff in Iran

Background and Aim: In angiography, the lens of the eye may be exposed to radiation and cause cataracts. In Iran, at present, only a single film dosimeter is used under the lead-apron to evaluate individual doses. The aim of this study was to investigate the status of occupational radiation as well as the validity of measuring the dose of the whole body of individuals and eye lenses using a sin...

متن کامل

An Eye on Travel: An Overview of Travel-Related Ocular Complications

Travellers are at risk of a diverse range of environmental and infectious conditions, some of which may affect the eyes and lead to blindness in severe cases. Travel-related ocular infections include onchocerciasis, leishmaniasis, cysticercosis, trachoma, dengue, loiasis, and leptospirosis. The travel medicine adviser should also recognise other hazards encountered during travel which may adver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 40 13  شماره 

صفحات  -

تاریخ انتشار 1999