Impact of prolonged 48-h wireless capsule esophageal pH monitoring on diagnosis of gastroesophageal reflux disease and evaluation of the relationship between symptoms and reflux episodes.

نویسندگان

  • Gerson Ricardo de Souza Domingues
  • Joaquim Prado P Moraes-Filho
  • Aline Gonçalves Leite Domingues
چکیده

CONTEXT Gastroesophageal reflux disease is one of the most common digestive diseases and an important cause of distress to patients. Diagnosis of this condition can require ambulatory pH monitoring. OBJECTIVES To determine the diagnostic yield of a wireless ambulatory pH monitoring system of 48-hours, recording to diagnose daily variability of abnormal esophageal acid exposure and its symptom association. METHODS A total of 100 consecutive patients with persistent reflux symptoms underwent wireless pH capsule placement from 2004 to 2009. The wireless pH capsule was deployed 5 cm proximal to the squamocolumnar junction after lower esophageal sphincter was manometrically determined. The pH recordings over 48-h were obtained after uploading data to a computer from the receiver that recorded pH signals from the wireless pH capsule. The following parameters were analyzed: (1) percentual time of distal esophageal acid exposure; (2) symptom association probability related to acid reflux. The results between the first and the second day were compared, and the diagnostic yield reached when the second day monitoring was included. RESULTS Successful pH data over 48-h was obtained in 95% of patients. Nearly one quarter of patients experienced symptoms ranging from a foreign body sensation to chest pain. Forty-eight hours pH data analysis was statistically significant when compared to isolated analysis of day 1 and day 2. Study on day 2 identified seven patients (30.4%) that would be missed if only day 1 was analyzed. Three patients (18.7%) out of 16 patients with normal esophageal acid exposure on both days, showed positive symptom association probability, which generated an increase in diagnostic yield of 43.4%. CONCLUSION Esophageal pH monitoring with wireless capsule is safe, well tolerated, does not require sedation. The extended 48-h period of study poses an increased yield to diagnose gastroesophageal reflux disease patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study of two modes of gastroesophageal reflux measuring: conventional esophageal pH monitoring and wireless pH monitoring.

CONTEXT Esophageal pH monitoring is considered to be the gold standard for the diagnosis of gastroesophageal acid reflux. However, this method is very troublesome and considerably limits the patient's routine activities. Wireless pH monitoring was developed to avoid these restrictions. OBJECTIVE To compare the first 24 hours of the conventional and wireless pH monitoring, positioned 3 cm abov...

متن کامل

Evaluation of Gastroesophageal Reflux Disease Using the Bravo Capsule pH System.

Gastroesophageal reflux disease (GERD) is a disease predominantly seen in the West but there is a rising trend in Asia. Ambulatory 24-hour catheter-based pH monitoring has been the de facto gold standard test for GERD that correlates symptoms with acid reflux episodes. However, drawbacks such as patients' discomfort, and catheter displacement render the test as cumbersome and error-prone. The B...

متن کامل

Ineffective esophageal motility and gastroesophageal reflux disease: a close relationship?

BACKGROUND/AIMS An association between ineffective esophageal motility and gastroesophageal reflux disease is already known, but there are also some conflicting data. We evaluated the association between ineffective esophageal motility and gastroesophageal reflux disease in patients who underwent ambulatory pH monitoring for the evaluation of reflux symptoms at Gazi University, Gastroenterology...

متن کامل

How to Interpret Esophageal Impedance pH Monitoring

Esophageal impedance pH monitoring provides quantitative data on esophageal acid exposure and has the ability to correlate the symptoms with acid exposure events. The nomenclature for the reflux patterns detected in impedance pH monitoring as well as the normal values have been determined. Data interpretation is similar to 24-hour pH monitoring, ie, searching for an increase in the number of re...

متن کامل

Clinical utility and tolerability of JSPH-1 wireless esophageal pH monitoring system

BACKGROUND Wireless esophageal pH monitoring system is an important approach for diagnosis of gastroesophageal reflux disease (GERD), the aim of this study is to test the tolerability and utility of the first wireless esophageal pH monitoring system made in China, and evaluate whether it is feasible for clinical application to diagnose GERD. METHODS Thirty patients from Department of Gastroen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos de gastroenterologia

دوره 48 1  شماره 

صفحات  -

تاریخ انتشار 2011