Suprasternal cross - sectional echoc ? - diography in assessment of patent ductus arteriosdis

نویسنده

  • Joseph Levy
چکیده

Ninety-four patients with patent ductus arteriosus, whose ages ranged from 28 weeks gestation to 8 years, were assessed by suprasternal cross-sectional echocardiography. A further group of 37 cases without a patent ductus arteriosus were assessed by the same technique. The appearances of the ductus via this approach varied according to the ventriculoarterial connections. Reliable assessment of patency was possible in 87 cases. In seven cases where the ductal lumen was less than 2 mm in size, a false negative diagnosis was made. In the 37 patients without a patent ductus arteriosus, no false positive diagnoses were made. Suprasternal cross-sectional echocardiography enables a reliable assessment of ductal patency, provided the lumen*falls within the range of lateral resolution of the equipment being used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Clinical Course of Patent Ductus Arteriosus after Discharge and Comparing in Therapies Techniques

Background Patent ductus arteriosus is an open channel between the aorta and pulmonary artery. The study aimed to evaluate the clinical course of patent ductus arteriosus after discharge and comparing in therapies technique. Materials and Methods This cross-sectional and inferential- descriptive study was performed in the hospitals of city of Zahedan-Iran in the period of one decade from 2005 ...

متن کامل

Real-time cross-sectional echocardiographic imaging and measurement of the patent ductus arteriosus in infants and children.

While echocardiography has been used to noninvasively document indirect effects on the heart of left-to-right shunting through a patent ductus arteriosus, no noninvasive technique has been developed to image the duct itself. In this study, 35 sequential studies were performed on 28 patients with a mechanical sector scanner to image the distal pulmonary artery and its bifurcation by scanning alo...

متن کامل

Patent ductus arteriosus in a lamb: A case report

Patent ductus arteriosus (PDA) is a persistent patency of a vessel normally present in the fetus that connects the pulmonary arterial system to the aorta. The ductus arteriosus fails to close at birth when breathing commences and placental blood circulation is removed. Closure of the ductus arteriosus arises in response to decline pulmonary vascular resistance and increased systemic vascular re...

متن کامل

Noninvasive visualization of the dilated main coronary arteries in coronary artery fistulas by cross-sectional echocardiography.

Real-time cross-sectional echocardiographic studies of the main coronary arteries were performed in 20 normal subjects, 12 patients with patent ductus arteriosus and 14 patients with coronary artery fistula in whom the diagnosis was established by angiography. In 12 patients, the coronary artery that formed the fistula was dilated: The right coronary artery was involved in eight and the left co...

متن کامل

Efficacy and complications of oral ibuprofen and intravenous acetaminophen in closure of patent ductus arteriosus of preterm neonates

Background: Previous studies have considered patent ductus arteriosus (PDA) a common finding in premature infants, leading to complications such as intracranial hemorrhage, necrotizing enterocolitis and pulmonary dysplasia. The aim of this study was to assess and compare the efficacy of oral ibuprofen and intravenous acetaminophen in the closure of arterial duct in premature newborns. We also e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003